ifm
System Manual
ecomat
mobile
SmartController (CR2500) V05
PWM in the ecomatmobile controller
Hydraulic control in PWM
193
Parameters of the function outputs
Name
Data type Description
OUT1
WORD
Standardised output value
pairs of values 0 to 10 [increments]
e.g. for valve left
OUT2
WORD
Standardised output value
pairs of values 0 to 10 [increments]
e.g. for valve right
OUT3
INT
Standardised output value
pairs of values 0 to 10 [increments]
e.g. for valve on output module
(e.g. CR2011 or CR2031)
WRONG_MODE
BOOL
Error: invalid mode
ERR1
BYTE
Error code for rising edge:
0 = no error
1 = error in array: wrong sequence
2 = initial value IN not contained in value range of array
4 = invalid number N for array
ERR2
BYTE
Error code for falling edge:
0 = no error
1 = error in array: wrong sequence
2 = initial value IN not contained in value range of array
4 = invalid number N for array
Содержание Ecomat Mobile Series
Страница 1: ...System Manual SmartController CR2500 CoDeSys V2 3 Target V05 7390675 00 10 2009...
Страница 6: ......