252
ifm
System Manual
ecomat
mobile
SmartController (CR2500) V05
More functions in the ecomatmobile controller
Processing analogue input values
10.8.3
Function INPUT_CURRENT
Contained in the library:
ifm_CRnnnn_Vxxyyzz.LIB
Available for the following devices:
•
CabinetController: CR0301, CR0302, CR0303
•
ClassicController: CR0020, CR0505
•
ExtendedController:
CR0200
•
SafetyController: CR7020, CR7200, CR7505
•
SmartController:
CR2500
Function symbol:
INPUT_CURRENT
ENABLE
ACTUAL_CURRENT
INPUT_CHANNEL
Description
INPUT_CURRENT processes analogue currents measured at the analogue channels.
The function returns the actual input current in [µA] at the analogue current inputs.
Info
INPUT_CURRENT is a compatibility function for older programs. In new programs, the more powerful
function INPUT_ANALOG (
→
page
) should be used.
Parameters of the function inputs
Name
Data type Description
ENABLE
BOOL
TRUE: function is executed
FALSE: function is not executed
INPUT_CHANNEL BYTE Analogue current inputs 4...7
Parameters of the function outputs
Name
Data type Description
ACTUAL_CURRENT
WORD
Input current in [µA]