Overview of CANopen error codes
Error Code
(hex)
Meaning
00xx
Reset or no error
10xx Generic
error
20xx Current
error
21xx
Current, device input side
22xx
Current inside the device
23xx
Current, device output side
30xx Voltage
31xx Mains
voltage
32xx
Voltage inside the device
33xx
Output voltage error
40xx Temperature
error
41xx
Ambient temperature error
42xx
Device temperature error
50xx
Device hardware error
60xx
Device software error
61xx
Internal software error
62xx User
software
63xx
Data set error
70xx Additional
modules
80xx Monitoring
81xx Communication
8110
CAN overrun – objects lost
8120
CAN in error passive mode
8130
Life guard error or heartbeat error
8140
Recovered from bus off
8150
Transmit COB-ID collision
82xx Protocol
error
8210
PDO not processed due to length error
8220
PDO length exceeded
90xx External
error
F0xx Additional
functions
FFxx Device-specific