49
2
INSTALLATION PROCEDURE
302.061
ERROR
CAUSE
CURE
After the selector switch on the
remote control panel has been tur-
ned to the “AUTOMATIC” position,
this message appears.
The “MANUAL” mode was actuated
from the keyboard on the bar fee-
der.
To actuate the “AUTOMATIC” mode
press the
push-button on
the bar feeder keyboard.
CAUSE
CURE
No value was set at
parameter 40
.
Enter the values in the subparameters.
ERROR
CAUSE
SOLUTION
During the 1st feeding stroke the
short feed control gate detected a
bar which is too long.
The bar exceeds the maximum loa-
dable length of bars.
Load bars of the maximum length
allowed, which corresponds to the
maximum length inside the lathe
spindle.
32
E r r o r : M a n u a l
f r o m
k e y b o a r d
33
( E r r o r : s u b - s p i n d l e
p a r a m e t e r s
w r o n g
34
( E r r o r : . . . )
35
E r r o r : b a r
t o o
l o n g