48
2
INSTALLATION PROCEDURE
302.061
ERROR
CAUSE
SOLUTION
The bar feeder has stopped due to
a fault.
Examples: Wrong bar-pusher move-
ment, bar not loaded in collet, bar
remnant missing, bar missing, etc..
Correct fault and reset with STOP
push-button.
ERROR
CAUSE
SOLUTION
The bar feeder is not locked but is
running.
The axial displacement device is not
locked.
Lock the axial displacement device.
The sensor is not providing the OK
signal.
Check that the sensor issues the
signal when the axial displacement
device is locked.
Check the correct operation of the
sensor.
ERROR
CAUSE
CURE
After the
key has been
pressed on the bar feeder keybo-
ard, this message appears.
The “MANUAL” mode was actuated
from the remote control panel on the
lathe.
Move the selector switch of the
remote control panel to the “AUTO-
MATIC” position.
28
R e s e t
w i t h
S T O P ! ! !
29
E r r o r : a x i a l
d i s p l a c e m e n t
n o t
l o c k e d
30
( E r r o r : . . . )
31
E r r o r : M a n u a l
f r o m
c o n t r o l
p a n e l
Содержание VIP 80
Страница 1: ...REL DATA COD S N VIP 80 MANUAL FOR USE AND MAINTENANCE GB 1 03 11 99 805005440 ...
Страница 28: ...HANDLING AND INSTALLATION 4 25 302 028 ...
Страница 52: ...MACHINE MAINTENANCE 7 302 028 49 7 2 3 Lubricating points fig 4 Lubricate Lubricate 4 28_063_3 bmp ...
Страница 61: ...PUSH BUTTON PANEL OPERATION GUIDE GB 03 11 99 VIP 80 AUTOMATIC BAR FEEDER ...
Страница 64: ...2 302 061 ...
Страница 74: ...12 1 GENERAL INFORMATION 302 061 ...
Страница 136: ......
Страница 138: ......
Страница 142: ...302 061 B ...
Страница 144: ......
Страница 148: ......
Страница 150: ......
Страница 152: ......