40
2
INSTALLATION PROCEDURE
302.061
ERROR
CAUSE
SOLUTION
The bar met the first obstacle in the
section defined by
parameter 11
and was not able to continue.
The bar cannot go through the collet
or the bushing of the lathe.
Check the diameter of the bushing.
If a shaped bar is being machined,
check that the introduction area is
suitable on the bar entry on the rear
of the collet.
If the bar is shaped, check the revo-
lutions of the spindle and that the
impulse sequence is correct.
Check the torque of the clutch
(
parameter 13
) and the feed set
(
parameter 12
).
Encoder fault.
Check that the encoder is driven
correctly in the rotation .
Check on the display the position of
the bar pusher carriage, and verify
that the position change indicated
corresponds to the actual move-
ment.
8
c o l l e t
E r r o r : t h e
b a r
f a i l s
t o
e n t e r
i n t o
t h e
C
parameter 11
IDM - 61.019 Ec.0