5 - ADJUSTMENT AND SETUP
Master 80 UP HyperFlexible
EN
5 - Pag. 21 / 21
5.4.2 Elevator carriage drive - Adjustment
The safety joint has to be adjusted so that the bar
is lifted and, at the same time, the motor drive is
deactivated when the bar cannot be lifted for
whatever reason.
Adjust as follows:
• Loosen screw (A);
• tighten or loosen ring nut (B);
• tighten screw (A).
WARNING - CAUTION:
do not screw the ring nut too much; the
joint could be locked.
5.4.3 Elevator carriages - Setup
Adjust the position of the bar gripping lever (A)
according to the bar diameter and section.
Adjust as follows:
• bring the elevator carriages at about half-stroke
by means of selector switch (B) to make the
operation easier;
• tighten or loosen screw (C).
Содержание Master 80 UP HyperFlexible
Страница 2: ......
Страница 4: ......
Страница 10: ......
Страница 16: ......
Страница 25: ...2 TECHNICAL INFORMATION Master 80 UP HyperFlexible EN 2 Pag 9 9 ...
Страница 36: ...EN 2 TECHNICAL INFORMATION Master 80 UP HyperFlexible 2 Pag 20 20 2 6 TECHNICAL DATA ...
Страница 44: ......
Страница 58: ......
Страница 66: ...EN 4 HANDLING AND INSTALLATION Master 80 UP HyperFlexible 4 Pag 8 8 tighten screws A and fit brackets B again ...
Страница 102: ......
Страница 106: ...EN 6 USE AND OPERATION Master 80 UP HyperFlexible 6 Pag 4 4 ...
Страница 127: ...7 BAR FEEDER MAINTENANCE Master 80 UP HyperFlexible EN 7 Pag 3 3 7 2 SCHEDULED MAINTENANCE Scheduled maintenance ...
Страница 132: ...EN 7 BAR FEEDER MAINTENANCE Master 80 UP HyperFlexible 7 Pag 8 8 7 3 LUBRICATION POINT DIAGRAM Oil ...
Страница 134: ...EN 8 TROUBLES CAUSES SOLUTIONS Master 80 UP HyperFlexible 8 Pag 2 2 ...
Страница 142: ......
Страница 174: ...EN 11 COLLETS Master 80 UP HyperFlexible 11 Pag 24 24 ...