Print More Materials, All For Application
- 22 -
For the first use
, when the platform rises to touch the
nozzle, if you hear a "bang" sound and the machine is
powered off, which indicates that the emergency stop
limit is triggered. Need to unplug the
limit connector
and open the right electric box cover, find the leakage
protector and press the gray button, switch up to start
the machine. After starting, drop the Z-axis and
connect the connector of the emergency stop limiter.
Adjust the height of the emergency stop limiter
according to the situation
If the limiter is triggered in advance, resulting in a
shutdown, you can adjust the limiter up a bit
according to step 6