References
Setup menus - Transmitter
52
Power cycle to allow changes to take effect.
Network setup
→
Gateway
Setting IP gateway
Items
Enter IP gateway address.
Enter IP address of gateway. Default value is 192.168.98.1.
Setting changes are not required if a router or IP gateway are not used.
Power cycle to allow changes to take effect.
Network setup > Codec Local IP
Setting IP address (2)
Items
Enter IP address.
Enter the codec module IP address which is built in the unit.
Default IP address of the transmitter is 192.168.98.112. Please change if it overlaps with
existing equipment on the LAN. Power cycle to allow changes to take effect.
Note:
Must be the same subnet as "Setting the IP address (1)".
For example.
Setting of the IP address (1): 192.168.111.10 Netmask 255.255.255.0
Setting of the IP address (2): 192.168.111.11
Video > H.264 profile
Setting H.264 profile
Items
Baseline / Main / High
Set the H.264 profile of downlink video transmission.
Baseline Baseline profile
Main
Main profile
High
High profile
Default setting is the High profile.
If the profile is changed during transmission, blackout and video distortion may occur.
Note:
Baseline Profile supports progressive video, but not supported interlaced video and PsF.
Video > Video bit rate
Setting H.264 bit rate
Items
3Mbps / 5Mbps / 10Mbps / 20Mbps / 25Mbps /
AUTO
Содержание CW-F25
Страница 1: ...CW F25 Instruction Manual for Europe IDX Company Ltd ...
Страница 67: ...References Specification 66 EN60950 1 RoHS ...
Страница 81: ......