Useful information
Troubleshooting
45
9)
GPI trouble
Please check Tally setting of the transmitter and receiver.
If remote tally is required, please select Remote Tally on the transmitter side and set
Tally
>
ON on the receiver side.
Check pin assignment of the GPI cable.
Please check the specifications of the equipment connected to the GPI output. Vcc of
the external device must be 24V or less and the current should be less than 40mA.
The GPI port does not supply power. Equipment with an ON/OFF switch dependent on
voltage will not work on this port.
10)
RS-422 trouble
Please check Remote settings. Default value is OFF. Set ON for use.
It will not communicate if the baud rate, data bits, parity, and stop bits, are not matched.
Please check the pin assignment of the RS-422 cable.
If using a long cable, please replace it with shorter a one.
CW-F25 does not support RS-232C.
11)
Ethernet trouble
Please check the IP address setting. Ensure the IP address is not a duplicate of another
device.
If connecting to an existing LAN network, please check the network address or IP
address of CW-F25. It is recommended to set the IP address of the CW-F25 to not
conflict with the subnet of existing LAN networks.
Pay attention when setting the IP address to avoid duplication, especially if the CW-F25
will operate on an existing LAN subnet.
When connecting to an existing LAN network, please do not connect the transmitter
and receiver at same time; the network will establish a wireless bridge and create a loop
in the LAN network. A path loop in the wireless bridge will cause performance
degradation. Eventually leading to a LAN network failure.