Useful information
Troubleshooting
41
IV. Useful information
1. Troubleshooting
Check the following before requesting for repair service. If the problem is not resolved,
please contact your dealer or our support & service team.
Please refer to P.78 "Support & Service contact".
1)
Power does not turn on
Check if the LED is emitting light. If it is lit or flashing, the power it turned ON. If the
LEDs are active, there is a possibility that the LCD backlight has failed.
Please make sure the input voltage is within specifications.
Voltage range of CW-F25 is DC7-17V.
Please check that the AC adaptor or power supply is turned ON.
Is the AC adapter connected to a commercial power source correctly?
Does the battery have sufficient capacity and output voltage?
Is the battery mounted to the P-V2CL correctly? The battery must be seated straight
down from the upper side of the V-Plate. Improper battery handling may damage the
pins on the V-Plate.
Is the polarity correct on the 4-pin Cannon connector?
Pin assignment of Cannon XLR-4 is: #1 = negative, #4 = positive.
Is the Cannon connector locked in place?
When installing the A-MT2V(CW), make sure the connection of both connectors are
firmly plugged in. When mounting, ensure that wires are not being pinched between the
A-MT2V(CW) and CW-F25.
2)
Status LED does not lit
Please check the power supply. Refer P.41 "Power does not turn on".
Status LED starts to emit about 15 second after the power is turned ON. This time
delay is caused by the circuit initialization time; it is not a malfunction.
3)
LCD backlight does not light
Please check the power supply. Refer P. 41 "Power does not turn on".