Operation of CW-F25
RS-422 remote
40
7.
Enable the RS-422 interface in the setup menu of receiver.
Remote > Interface > RS-422
* Default setting is OFF.
Last setting is memorized even after power is turned OFF.
8.
Set communication parameters of RS-422 in the settings menu of the receiver.
Remote > Baud rate > Select baud rate.
* Default is 38400 bps.
Remote > Data bit > Select data bit length.
* Default is 8 bit.
Remote > Parity > Select parity.
* Default is "none".
Remote > Stop bit > Select stop bit length.
* Default is 1 bit.
Last setting is memorized even after power is turned OFF.
9.
CW-F25 setup is successful when two-way transmission of RS-422 is active.
RS-422 cable and connector
RS-422 connector is a D-Sub 9 pin female.
Please refer to P. 70 "Connector and pin assignment".
Please prepare RS-422 cable, locally.
Note
A transmission delay occurs due to in radio transmission. The amount of delay depend
on the environment and transmission distance. Please test prior to using the system.