MSD-804FD
User’s Guide
141
7.11.4
LAN operation mode [FUNCTION]
Set the LAN operation mode consisting of “RECEIVER” mode that controls the MSD externally and
“TRANSMITTER” mode that controls external devices from the MSD.
If you select “TRANSMITTER” mode, you need to set the IP address of the device and the port number to be
connected. The MSD can establish up to eight connections and the operation mode can be set separately.
If HDBaseT output option is mounted, peripheral devices can be controlled via LAN of the twisted pair cable
receiver (HDC series) for each output. The operation mode of HDBaseT output is fixed at
“TRANSMITTER”.
[Table 7.9] Setting items of LAN operation mode
Item
Description
Range
FUNCTION
*1*2
Controlling the MSD externally or controlling
external devices from MSD.
RECEIVER [Default]
TRANSMITTER
IP
*3
IP address of target device
4 bytes between 0 to 255
[Default] 192.168.001.198
PJLink
*3
Whether you use PJLink (class1) for projector
control or not.
OFF : PJLink is not used. [Default]
ON : PJLink is used.
PORT
*3 *4
Port number for “TRANSMITTER” mode.
(Set the port number for “RECEIVER” mode
in “
7.11.5
”.)
1 to 65535 [Default]: 1100
Make sure the port number is correct,
because reserved port number that is
only for specific purpose can also be
selected technically.
PASSWORD
*3 *5
Password for authentication at PJLink protocol
connection (up to 32 characters).
Not necessary if you do not perform the
authentication with password.
30 to 39, 41 to 5A, and 61 to 7A
(alphanumeric character) of ASCII
codes.
Final character: 20 (space) [Default]
*1
[Table 7.10] LAN operation mode
Mode
External control
Controlling external devices using ”
7.12
”
RECEIVER mode
Can be used
Cannot be used
*6
TRANSMITTER mode
Cannot be used
*7
Can be used
*2
Operation mode of OUT1B to OUT4B is fixed at
“TRANSMITTER”.
*3
If selecting “RECEIVER” for operation mode, you do not need to set the item.
*4
If selecting “ON” for PJLink protocol, the target port number is fixed at “4352”.
*5
If selecting “OFF” for PJLink protocol, you do not need to set the item.
*6
Connections that are
set to “RECEIVER” cannot be used for controlling external devices.
*7
Connections that are
set to “TRANSMITTER” cannot be used for controlling the MSD externally.