4
iDirect Evolution X1 Satellite Router Installation and Safety Manual
Installation Guidelines
2.1 Installation Guidelines
When installing the Evolution X1 router, observe all caution and warning statements. Follow
the general warnings and cautions in
Table 1
to help ensure your safety and protect the
equipment. However, these guidelines may not cover all of the potentially hazardous
situations you may encounter during installation.
The installation of the IDU must comply with the national and local electrical codes, as
follows:
•
In the United States, the National Fire Protection Association (NFPA) 70, United States
National Electric Code.
•
In Canada, the Canadian Electric Code, Part 1, CC22.1
•
In other countries, the International Electromechanical Commission (IEC)
Recommendation 364, part 1 through part 7.
•
All cables (IFL or other types) that run from the outdoor equipment to the indoor
equipment must be connected to a surge protector at the point of entry to the building.
•
Equipment connected to the protective grounding of the building installation through the
mains connection or through other equipment with a connection to protective grounding,
and to a cable distribution system using coaxial cable, may in some circumstances create
a fire hazard. Connection to a cable distribution system must be made through a device
providing electrical isolation below a certain frequency range (galvanic isolator, see EN
60728-11).
Review the safety instructions in this chapter, and the safety warnings and compliances
beginning in
Appendix A, "Warnings"
, of this manual before installing, configuring, or
performing maintenance on the system.
•
Always remove or disconnect ALL power connections before installing or removing a
chassis.
•
Keep the staging area clear and free of dust during and after installation.
•
Keep tools, IDU components, and shipping boxes away from walkway area.
•
The IDU operates safely when it is used in accordance with its marked electrical ratings
and product usage instructions.
•
In Norway, due to regulation for installations of cable distribution systems, and in
Sweden, a galvanic isolator shall provide electrical insulation below 5 MHz. The insulation
shall withstand a dielectric strength of 1.5 KV rms, 50 Hz or 60 Hz, for 1 minute.
•
Utstyr som er koplet til beskyttelsesjord via nettplugg og/eller via annet jordtilkoplet
utstyr – og er tilkoplet et kabel-TV nett, kan forårsake brannfare. For å unngå dette
skal det ved tilkopling av utstyret til kabel-TV nettet installeres en galvanisk isolator
mellom utstyret og kabel- TV nettet.
•
Utrustning som är kopplad till skyddsjord via jordat vägguttag och/eller via annan
utrustning och samtidigt är kopplad till kabel-TV nät kan i vissa fall medf
ő
ra risk f
ő
r
brand. F
ő
r att undvika detta skall vid anslutning av utrustningen till kabel-TV nät
galvanisk isolator finnas mellan utrustningen och kabel-TV nätet.
Содержание Evolution X1
Страница 1: ...Installation and Safety Manual Evolution X1 Satellite Router Router Products March 27 2012...
Страница 4: ...iv iDirect Evolution X1 Satellite Router Installation and Safety Manual...
Страница 8: ...viii iDirect Technical Publications Template 08 13 2010...
Страница 14: ...2 iDirect Evolution X1 Satellite Router Installation and Safety Manual...
Страница 58: ...46 iDirect Evolution X1 Satellite Router Installation and Safety Manual Declaration of Conformity...
Страница 59: ......
Страница 60: ......