41
3. Press the ENTER key to access Wet Pump Flow Calibration screen.
P U M P F L O W
W E T C A L
4.
Press the ENTER key to begin Flow Calibration
S E T M O T O R S P E E D
H I G H : 1 8 0 0 R P M
5.
Using the UP and/or DOWN arrow keys adjust the motor speed to a high flow speed setpoint. The speed set is the
high speed calibration point for the MPC VECTOR that you will measure flow at.
6.
Press the ENTER key to accept the calibration speed.
P R E S S E N T E R T O
S T A R T M O T O R
T
HE MOTOR WILL START WHEN THE ENTER KEY IS PRESSED
.
MAKE SURE THAT YOUR SYSTEM IS
PREPARED FOR OPERATIONS BEFORE STARTING THE MOTOR
.
7.
Press the ENTER key to start the motor. The system advances to the draw down interval count down screen.
The default interval will be 60 seconds. At any time, pressing the ENTER key will take the user immediately to
the next screen. This allows for shorter drawdowns using the ENTER key. All other keys abort the calibration.
R U N N I N G 6 0 S E C S * *
( W I L L C O U N T D O W N )
M O T O R : 1 8 0 0 R P M
* * 6 0 S E C O N D S W I L L E L A P S E B Y D E F A U L T
8.
Based upon your drawdown interval and volume dispensed, calculate the high speed calibration flow rate value.
Using the UP and/or DOWN arrow keys adjust the flow to your calculated value.
F L O W A T 1 8 0 0 R P M
F L O W : 2 5 . 0 0 G P H
9.
Press the ENTER key to accept the calibration flow rate and proceed to the low speed calibration point.
10.
Using the UP and/or DOWN arrow keys adjust the motor speed to an approximate low speed setpoint. This speed
is the low speed calibration point for the MPC VECTOR that you will measure flow at.
S E T M O T O R S P E E D
L O W : 1 8 0 R P M
11.
Press the ENTER key to accept the calibration speed.
P R E S S E N T E R T O
S T A R T M O T O R
T
HE MOTOR WILL START WHEN THE ENTER KEY IS PRESSED
.
MAKE SURE THAT YOUR SYSTEM IS
PREPARED FOR OPERATIONS BEFORE STARTING THE MOTOR
.
Содержание Pulsafeeder MPC Vector
Страница 6: ......
Страница 14: ...8 Figure 1 3 Closed Loop Control Feedback Block Diagram Figure 1 4 Closed Loop Flow Calibration Curve...
Страница 43: ...37 This page is intentionally left blank...
Страница 73: ...67 Continues next page...
Страница 80: ...74 16 Menu Maps...
Страница 81: ...75...
Страница 82: ...76...
Страница 83: ...77...
Страница 84: ...78...
Страница 85: ...79...
Страница 86: ...80...
Страница 87: ...81...
Страница 88: ...82...
Страница 89: ...83...
Страница 90: ...84...
Страница 91: ...85...
Страница 92: ...86...
Страница 93: ...87...
Страница 94: ...88...
Страница 95: ...89...
Страница 96: ...90...
Страница 97: ...91...
Страница 105: ...99 Figure 8 Handheld Remote...
Страница 112: ......
Страница 113: ......
Страница 114: ...and Keypad Functionality BULLETIN No IOM MPCVector UMPC 11 201010 Rv A...