2. Installation & wiring
Function
4. Support tool
5. Appendix
1. Overview
3-38
Configuration item table
Item
Sub item
Address
(hex)
Size
(dec)
Default
(hex)
Setting value
(hex)
Remarks
PWM output
settings
PWM output
frequency when failed
014A
2
F4
0014-4E20: Setting value Hz
(20 Hz to 20,000 Hz)
Lower byte setting
014B
01
Upper byte setting
PWM output
duration when failed
014C
1
14
00: Infinity
01-FF: Setting value by 10ms step
(10 ms to 2,550 ms)
Open state when the output stops.
PWM output
duty when failed
014D
1
32
01-63: Setting value %
(1% to 99%)
Set the percentage when on.
Reserved
014E
1
-
-
Reserved
014F
1
-
-
Indicator LED
settings
Indicator LED (green)
reading linked control
0150
1
01
00: Disabled
01: Enabled
Enable to link to the reading
operation.
Reserved
0151
1
-
-
-
Indicator LED (green)
illumination pattern
0152
1
01
00: Off
01: On
02: Flashing (high speed)
03: Flashing (medium speed)
04: Flashing (low speed)
Indicator LED (green)
illumination time
0153
1
1E
00: Infinity
01-FF: Setting value by 10ms step
(10 ms to 2,550 ms)
Indicator LED (red)
reading linked control
0154
1
01
00: Disabled
01: Enabled
Enable to link to the reading
operation.
Reserved
0155
1
-
-
Indicator LED (red)
illumination pattern
0156
1
01
00: Off
01: On
02: Flashing (high speed)
03: Flashing (medium speed)
04: Flashing (low speed)
Indicator LED (red)
illumination time
0157
1
1E
00:
Infinity
01-FF: Setting value by 10ms step
(10 ms to 2,550 ms)
Indicator LED (orange)
reading linked control
0158
1
01
00: Disabled
01: Enabled
Enable to link to the reading
operation.
Reserved
0159
1
-
-
Indicator LED (orange)
illumination pattern
015A
1
01
00: Off
01: On
02: Flashing (high speed)
03: Flashing (medium speed)
04: Flashing (low speed)
Indicator LED (orange)
illumination time
015B
1
00
00: Infinity
01-FF: Setting value by 10ms step
(10 ms to 2,550 ms)
Reserved
015C
1
-
-
Reserved
015D
1
-
-
Reserved
015E
1
-
-
Reserved
015F
1
-
-
Operation button
settings
Reading start
with Operation button
0160
1
01
00: Disabled
01: Enabled
Enable when you want to perform
reading with the operation of the
Operation button.
Reserved
0161-016F
15
-
-
Содержание WB1F Series
Страница 1: ...B 1775 6 WB1F Fix Linear CCD Scanner User s Manual...
Страница 115: ...B 1775 6 September 2019...
Страница 116: ...B 1775 6...