2. Installation & wiring
Function
4. Support tool
5. Appendix
1. Overview
3-40
Configuration item table
Item
Sub item
Address
(hex)
Size
(dec)
Default
(hex)
Setting value
(hex)
Remarks
Output data
additional
information
Global
prefix addition
0280
1
00
00: Disabled
01: Enabled
Global
suffix addition
0281
1
01
00: Disabled
01: Enabled
Local
prefix addition
0282
1
00
00: Disabled
01: Enabled
You can set the data to be added
to each type of barcode.
Local
suffix addition
0283
1
00
00: Disabled
01: Enabled
You can set the data to be added
to each type of barcode.
Data size addition
0284
1
00
00: Disabled
01: Enabled
Reserved
0285
1
-
-
Elapsed time addition
0286
1
00
00: Disabled
01: Enabled
AIM ID addition
0287
1
00
00: Disabled
01: Enabled
Reserved
0288
1
-
-
Label direction
addition
0289
1
00
00: Disabled
01: Enabled
Code length addition
028A
1
00
00: Disabled
01: Enabled
Reserved
028B
1
-
-
Check digit addition
028C
1
00
00: Disabled
01: Enabled
Label option addition
028D
1
00
00: Disabled
01: Enabled
Collectively output
separator specification
028E
1
00
00: Disabled
01: Enabled
Output addition
when reading failed
028F
1
01
00: Disabled
01: Enabled
No response
when reading failed
0290
1
00
00: Disabled
01: Enabled
When the setting value is en-
abled and the WB1F fails reading
the barcode, no data is output.
Reserved
0291-0293
3
-
-
Number of decoding
times addition
0294
1
00
00: Disabled
01: Enabled
Reserved
0295-0297
2
-
-
Output string data
when reading failed
0298
8
3F
00-FF: ASCII code
The initial state is a "?" response
when reading fails.
0299
00
00-FF: ASCII code
029A
00
00-FF: ASCII code
029B
00
00-FF: ASCII code
029C
00
00-FF: ASCII code
029D
00
00-FF: ASCII code
029E
00
00-FF: ASCII code
029F
00
00-FF: ASCII code