Installation & wiring
3. Functions
4. Support tool
5. Appendix
1. Overview
2-3
Mounting methods
2. 2 Mounting methods
RS-232 Type
USB Type
2. 2. 1 WB1F mounting methods
1
Check the dimensions of the mounting holes and drill holes in the mounting plate.
For the dimensions of the mounting holes, refer to
P. 5-4 "5. 3 Dimensional outline drawings"
2
For a plate thickness of 0.8 to 2.3 mm, use the two included product mounting screws and secure the WB1F to
the plate.
The tightening torque for the product mounting screws is 0.4 to 0.5 N·m.
Included product
mounting screws
M3 SEMS x 6 (2 screws)
Plate thickness 0.8 to 2.3 mm
When using the included product
mounting screws
z
For a plate thickness other than 0.8 to 2.3 mm, do not use the included product mounting screws.
Instead, use two M3 screws with an effective thread length of 3 to 5 mm and secure the WB1F to the
plate.
z
When using the WB1F, remove the protective film on the reading window.
z
For a plate thickness other than 0.8 to 2.3 mm, do not use the included product mounting screws.
z
Do not over tighten the mounting screws or hit the product with a hammer or the protective construc-
tion will be damaged.