2. Installation & wiring
Function
4. Support tool
5. Appendix
1. Overview
3-57
Configuration item table
Item
Sub item
Address
(hex)
Size
(dec)
Default
(hex)
Setting value
(hex)
Remarks
Decoder
MSI/Plessey
Reading allowed/
prohibited
0A20
1
00
00: Reading prohibited
01: Reading allowed
Label direction
specified reading
0A21
1
00
00: Not specified
01: Forward only
02: Reverse only
Inspection of
check digit
0A22
1
00
00: Disabled
01: Enabled
For details, refer to
.
Check digit sending
0A23
1
02
00: Not send
01: Send 1 digits
02: Send 2 digits
Left margin rate
0A24
1
00
00: Normal
01-06: 1/7-6/7
For details, refer to
.
Reserved
0A25-0A29
5
-
-
Check digit type
selection
0A2A
1
00
00: MOD10
01: MOD10+MOD10
02: MOD10+MOD11
03: MOD11+MOD10
Reserved
0A2B
1
-
-
Reserved
0A2C
1
-
-
Reserved
0A2D
1
-
-
Fixed length A
0A2E
1
03
01-40 (1 digit to 64 digits) For details, refer to
"Methods to fix the length of
read barcodes"
Fixed length B
0A2F
1
40
01-40 (1 digit to 64 digits)
Decoder
Italian Pharm
(Code32)
Reading allowed/
prohibited
0A30
1
00
00: Reading prohibited
01: Reading allowed
Label direction
specified reading
0A31
1
00
00: Not specified
01: Forward only
02: Reverse only
Inspection of
check digit
0A32
1
00
00: Disabled
01: Enabled
For details, refer to
.
Check digit sending
0A33
1
01
00: Not send
01: Send
Reserved
0A34
1
-
-
Add prefix A
0A35
1
00
00: Disabled
01: Enabled
Reserved
0A36-0A3F
10
-
-
Decoder
CIP39
Reading allowed/
prohibited
0A40
1
00
00: Reading prohibited
01: Reading allowed
Label direction
specified reading
0A41
1
00
00: Not specified
01: Forward only
02: Reverse only
Inspection of
check digit
0A42
1
00
00: Disabled
01: Enabled
For details, refer to
.
Check digit sending
0A43
1
01
00: Not send
01: Send
Reserved
0A44
1
-
-
Reserved
0A45
1
-
-
Start/stop character
sending
0A46
1
00
00: Not send
01: Send
Reserved
0A47-0A4F
9
-
-