background image

Vanderbilt International (IRL) Ltd.

 

 

 

 

 

 
Card reader 

ARS6311-RX 

Configuration Manual 

 

Содержание ARS6311-RX

Страница 1: ...Vanderbilt International IRL Ltd Card reader ARS6311 RX Configuration Manual...

Страница 2: ...ne unsere vorg ngige schriftliche Erm chtigung ganz oder teilweise Dritten zug nglich machen oder au erhalb des Zweckes verwenden zu dem es ihm bergeben worden ist We reserve all rights in this docume...

Страница 3: ...3 Connecting the reader 16 5 3 1 Ports 16 5 3 2 Wiegand Transmission Format 16 5 3 3 Magstripe Transmission Format 17 5 3 4 Address setting 17 6 Programming 18 6 1 Setting Reader Operation Mode 19 6 1...

Страница 4: ...4 Vanderbilt International IRL Ltd 05 2016...

Страница 5: ...for unsuitably or incorrectly set parameters whether automatic or manual or for inappropriate use of the unit All repairs must be carried out by the manufacturer The user is responsible for ensuring...

Страница 6: ...protection IP 65 Dimensions 100 x 40 x 25 mm Cable length 400 mm Weight Approx 110 g Approvals CE I O Board ACS6311 Input voltage 10 16 V DC Current consumption 100 mA both relays activated Inputs Two...

Страница 7: ...ata transmission formats available for use in ONLINE Mode which include the popular Wiegand and Magstripe i e simulation of output of a magnetic card reader data protocols When configured for Stand al...

Страница 8: ...Support for Door Contact DC and Request To Exit REX push button Door Alarm and Door Bell outputs Integration to intrusion alarm system through I O s Entry Exit control requires two ARS6311 RX to form...

Страница 9: ...user to whom the programmed card will belong as a result the reader simply stores the programmed card with the unoccupied user ID number The full programming procedure requires you to specify an ID nu...

Страница 10: ...fter Memory Reset the reader always enters ARMED Mode 4 4 3 Arming and Disarming of the Reader re arming Changing the reader s state from ARMED to DISARMED and back is called re arming in this manual...

Страница 11: ...ring Time The lock acti vation is signaled on LED OPEN green which remains on for as long as the door lock is energized When access to the supervised room is denied the reader generates a long beep Th...

Страница 12: ...the door is closed If more than one alarm is triggered the reader indicates the alarm with the highest priority The Forced Entry and the Door Ajar alarms Door Held will occur only if the reader opera...

Страница 13: ...Legend one long audible signal one short audible signal beep LED Indications in Stand alone Operation Mode LED STATUS LED OPEN LED SYSTEM Description Green The reader is in DISARMED State Red The rea...

Страница 14: ...g separate power supply sources connect all power supply negative leads together We recommend to ground the negative power supply lead With its relatively weak electromagnetic field generation the ter...

Страница 15: ...Installation 15 Vanderbilt International IRL Ltd 05 2016 5 1 Opening the housing Fig 1 Opening the housing 5 2 Mounting Fig 2 Mounting direction...

Страница 16: ...t used 5 3 2 Wiegand Transmission Format Fig 3 Wiegand Transmission Format When employing Wiegand transmission format the data is transferred using se quences of pulses sent over the CLOCK and DATA li...

Страница 17: ...indicators and the buzzer are controlled in the same manner as described for Wiegand for mats see previous section In Magstripe format the ARS6311 RX send the serial number of the card The default se...

Страница 18: ...using the adequate Programming Card use your Master Card when in User Programming Mode or use your Installer Card when in Installer Programming Mode The AR6311 RX can be programmed by multiple reading...

Страница 19: ...slave reader connected to master ARS6311 RX Use this mode for two way door control systems 04 OFFLINE Mode Stand alone Mode The reader operates as a Stand alone Unit its CLOCK and DATA lines are used...

Страница 20: ...mple Configuring the ARS6311 RX for Offline Mode Stand alone Mode Code 04 1 Power down the unit 2 Remove all connections from DATA bn and IN1 lines ye 3 Connect DATA bn to IN1 ye 4 Restore power the r...

Страница 21: ...IN1 ye 7 Present any card to the reader this card becomes a new Master Card 8 Present any other card to the reader this card becomes a new Installer Card 9 Once the previous step has been completed th...

Страница 22: ...6 3 1 Configuration Default settings Configuring the reader for the following set of installer s options Start programming using the installer card Enter the values for the parameters C1 to C11 succes...

Страница 23: ...r Card 1 time to the reader program C3 1 Wait for the acoustic prompt 5 Present your Installer Card 1 time to the reader program C4 1 Wait for the acoustic prompt 6 Present your Installer Card 4 times...

Страница 24: ...s access 3 Arming Disabled Input when the line is shorted to the power supply minus the reader can not be armed 4 Door Lock Output used to activate the door releasing device an electric lock or an ele...

Страница 25: ...A new user is registered in the terminal s memory at the location cor responding to his specified ID number he is assigned the proximity card presented in the last step of the command Add one Normal...

Страница 26: ...r has registered the new user card in its memory and exited the pro gramming function however it has not left User Programming Mode so that now you may use your next desired programming command or you...

Страница 27: ...27 Vanderbilt International IRL Ltd 05 2016 7 Appendix 7 1 Dimensions Fig 5 Dimensions 1 Tamper 2 Electronic circuit board fully potted 3 Cable length 400 mm LED STATUS ARMED DISARMED Mode LED OPEN LE...

Страница 28: ...16 7 2 Various example Connections 7 2 1 Reader in Stand alone Mode I O Board Fig 6 Stand alone Mode 1 Door Lock 2 Door Contact NC type 3 Exit Button NO type 4 Alarm Signaling Device 5 Buffered Power...

Страница 29: ...t or the local authorities This crossed out wheeled bin symbol on the product means the product is covered by the European Directive 2002 96 EC The correct disposal and separate collection of your old...

Страница 30: ...Appendix 30 Vanderbilt International IRL Ltd 05 2016 7 5 List of Users Site name Reader location ID number Card number Type User name Master Installer...

Страница 31: ...Appendix 31 Vanderbilt International IRL Ltd 05 2016 List of Users Site name Reader location ID number Card number Type User name...

Страница 32: ...ness and Technology Park Clonshaugh Dublin 17 Ireland www vanderbiltindustries com 2015 Copyright by Vanderbilt International IRL Ltd Data and design subject to change without notice Supply subject to...

Отзывы: