2 Character Input
9-38
SmartAXIS Touch User’s Manual
■
Without Pressing the Character Input, Directly Entering Text from a Keypad on the Same Screen
Arrange a Character Input and a keypad on the same screen. In the properties dialog box for the Character Input, on
the
General
tab, under
Keypad
, select
Current Screen
for
Type
and select the
Always Entry Mode
check box.
■
Changing the Language and Entering Text
Select the
Change Font with Device
check box on the
Format
tab in the properties dialog box.
It is convenient to use this setting together with the text group settings.
The font and Popup Screen with this setting will change simultaneously with the text group change and text can be
entered with the same font as the text group.
Select the
Use Dynamic Text
check box in the Text Group Settings dialog box and specify the same device in
Trigger Device
as the
Trigger Device
for this setting.
2.5 String Data Storage Method
The entered text is stored in the upper byte and lower byte according to the
Storage Method of String Data
setting.
Storage Method of String Data
is configured on the
System
tab in the Project Settings dialog box.
For details, refer to Chapter 3 “3.1 System Tab” on page 3-19.
Example: When the destination device is LDR100 and the entered text is ABCDE
• When
from Upper byte
is selected for
Storage Method of String Data
• When
from Lower byte
is selected for
Storage Method of String Data
External device
Touch
FT_
FT SERIES_
FT SERIES
D100 :
4654
(Hex)
‘F’ ‘T’
D100 :
D101 :
4654
(Hex)
‘F’ ‘T’
2053
(Hex)
4552
(Hex)
4945
(Hex)
5300
(Hex)
‘E’ ‘R’
D102 :
D103 :
D104 :
D100 :
D101 :
4654
(Hex)
‘F’ ‘T’
2053
(Hex)
4552
(Hex)
4945
(Hex)
5300
(Hex)
‘E’ ‘R’
D102 :
D103 :
D104 :
‘ ’ ‘S’
‘ I ’ ‘E’
‘S’
(NULL)
‘ ’ ‘S’
‘ I ’ ‘E’
‘S’
(NULL)
Write text character
codes to devices
Press
ENT
Display values of device as text
(Entry mode)
Display values of device as text
(Entry mode)
Display values of device as text
(Entry mode)
Enter text as
"FT SERIES"
Device
Stored value
Upper byte
Lower byte
LDR100
'A' = 41 (Hex)
'B' = 42 (Hex)
LDR101
'C' = 43 (Hex)
'D' = 44 (Hex)
LDR102
'E' = 45 (Hex)
0
NULL terminating character
Device
Stored value
Upper byte
Lower byte
LDR100
'B' = 42 (Hex)
'A' = 41 (Hex)
LDR101
'D' = 44 (Hex)
'C' = 43 (Hex)
LDR102
0
'E' = 45 (Hex)
NULL terminating character
When handling strings, 0 is written to the device as the NULL terminating character and treated as the end
of the string.
Содержание SmartAXIS Touch FT1A Series
Страница 1: ...FT1A Series FT9Y B1390 4 SmartAXIS Touch User s Manual ...
Страница 22: ...Contents Preface 21 SmartAXIS Touch User s Manual ...
Страница 240: ...6 Using Library Screens 4 36 SmartAXIS Touch User s Manual ...
Страница 416: ...2 Multi State Lamps 8 26 SmartAXIS Touch User s Manual ...
Страница 558: ...9 Calendar 9 142 SmartAXIS Touch User s Manual ...
Страница 668: ...6 Timer 11 52 SmartAXIS Touch User s Manual ...
Страница 754: ...4 Using Data and Detected Alarms 13 34 SmartAXIS Touch User s Manual ...
Страница 792: ...4 Using the Data 14 38 SmartAXIS Touch User s Manual ...
Страница 810: ...4 Using the Data 15 18 SmartAXIS Touch User s Manual ...
Страница 870: ...3 Text Manager 19 16 SmartAXIS Touch User s Manual ...
Страница 924: ...6 Important Notes 20 54 SmartAXIS Touch User s Manual ...
Страница 1036: ...5 User Communication 22 74 SmartAXIS Touch User s Manual ...
Страница 1092: ...2 Monitoring on the Touch 24 26 SmartAXIS Touch User s Manual ...
Страница 1142: ...2 Word Devices 27 18 SmartAXIS Touch User s Manual ...
Страница 1186: ...2 Analog Cartridge 29 34 SmartAXIS Touch User s Manual ...
Страница 1194: ...3 Handling Problems 30 8 SmartAXIS Touch User s Manual ...