![IDEC SmartAXIS Touch FT1A Series Скачать руководство пользователя страница 778](http://html.mh-extra.com/html/idec/smartaxis-touch-ft1a-series/smartaxis-touch-ft1a-series_user-manual_617387778.webp)
3 Data Log Settings Dialog Box
14-24
SmartAXIS Touch User’s Manual
■
Target Data
Selects the data to copy from the Data Log data.
Example: When
Start No.
is 2 and
End No.
is 4, data 2 to 4 is the copy target.
■
Trigger Condition
Selects the condition to start copying.
Sampling Time:
Select this check box to copy the sampling time data from the Data Log data. When this check
box is selected, values of devices are copied in order from the data for data number 1.
Value of Device:
Select this check box to copy the value of device from the Data Log data.
Data No.:
Selects the specification method for the data number of the value to copy.
Value:
Uses a constant.
Device:
Uses a word device.
Start No.:
Of the data to copy, specifies the data number of the data to start
copying.
If you select
Value
, specify the data number (1 to 128).
If you select
Device
, specify the source device. You can only
specify an internal device. For the device address configuration
procedure, refer to Chapter 2 “5.1 Device Address Settings” on
page 2-62.
When the
Sampling Time
check box is selected, the data number
is 1. This cannot be changed.
End No.:
Of the data to copy, specifies the data number of the data to end
copying.
If you select
Value
, specify the data number (1 to 128).
If you select
Device
, specify the source device. You can only
specify an internal device. For the device address configuration
procedure, refer to Chapter 2 “5.1 Device Address Settings” on
page 2-62.
Start No.
End No.
Data No.:
1
2
3
4
5
↓
↓
↓
↓
↓
Sampling Time
Data 1
Data 2
Data 3
Data 4
Data 5
10/01/2011 12:34:56
100
60
240
60
240
10/02/2011 03:45:12
200
80
450
80
450
Copy target
Always:
Copies each time the data is updated.
Device:
Specifies the device that triggers the start of copying the data. Copies the data when the value
of the specified device changes from 0 to 1.
For the device address configuration procedure, refer to Chapter 2 “5.1 Device Address
Settings” on page 2-62.
Содержание SmartAXIS Touch FT1A Series
Страница 1: ...FT1A Series FT9Y B1390 4 SmartAXIS Touch User s Manual ...
Страница 22: ...Contents Preface 21 SmartAXIS Touch User s Manual ...
Страница 240: ...6 Using Library Screens 4 36 SmartAXIS Touch User s Manual ...
Страница 416: ...2 Multi State Lamps 8 26 SmartAXIS Touch User s Manual ...
Страница 558: ...9 Calendar 9 142 SmartAXIS Touch User s Manual ...
Страница 668: ...6 Timer 11 52 SmartAXIS Touch User s Manual ...
Страница 754: ...4 Using Data and Detected Alarms 13 34 SmartAXIS Touch User s Manual ...
Страница 792: ...4 Using the Data 14 38 SmartAXIS Touch User s Manual ...
Страница 810: ...4 Using the Data 15 18 SmartAXIS Touch User s Manual ...
Страница 870: ...3 Text Manager 19 16 SmartAXIS Touch User s Manual ...
Страница 924: ...6 Important Notes 20 54 SmartAXIS Touch User s Manual ...
Страница 1036: ...5 User Communication 22 74 SmartAXIS Touch User s Manual ...