3 CC-Link IE Field Basic Communication (Slave)
KW2D Series Smart RFID Reader User’s Manual
4-21
4
Co
m
m
un
ica
tio
n F
un
ctio
n
■
Link device RY (0 to 3F)
The host device (master station) can write the value to the coil relay of the KW2D Smart RFID Reader via RY.
■
Link device RWw (0 to 1F)
The host device (master station) can write the value to the holding register of the KW2D Smart RFID Reader via RWw.
Shared Memory
CC-Link IE Field Basic Slave
Device Name
Address No.
Device Name
Address No.
Coil Relay
0001
RY
0
0002
1
…
…
0063
3E
0064
3F
Shared Memory
CC-Link IE Field Basic Slave
Device Name
Address No.
Device Name
Address No.
Holding Register
0001
RWw
0
0002
1
…
…
0031
1E
0032
1F