01.07.2022
15 / 70
AHP60-14/18 -
Installation, Use and Maintenance
2. DESCRIPTION OF THE EQUIPMENT
2.1. Designations and scope
Ecomod is hot water production system for heating networks or thermodynamic production
of domestic hot water.
2.2. Packaging
.
Outdoor unit
Model
Code
ECOMOD 14
AH090911
ECOMOD 18
AH090913
ECOMOD 14 AC
AH090912
ECOMOD 18 AC
AH090914
Other accessories according to connection - see Ecomod manual, heating application or DHW
application. The AC version has an anti-corrosion treatment of the evaporator. The performance
of the heat pump can be impacted by up to 2% compared to the values communicated in chap-
ter 2.4.1
2.3.
Definitions
Change to monobloc heat pump : to be installed outdoors only for heating and/or domestic hot
water application .
air/water : The outdoor air is the energysource. This energy is transmitted to the primary water
circuit by the heat pump.
inverter : The fan and compressor speeds are modulated to suit the heat requirements which
allows the noise level to be reduced. This technology makes it possible to save energy by avoiding
high starting currents and by adjusting the power to the load.
COP (coefficient of performance)
: instantaneously, this is the ratio between the energy transmitted
to the heating circuit and the electrical energy consumed.
DHW : Domestic hot water
CAUTION:
The minimum admissible temperature for the storage of the units is 5°C.