56 / 70
00U07352240-A_ EN
AHP60 14/18 kW -
Installation, Use and Maintenance
T [°C]
R [Ohm]
T [°C]
R [Ohm]
-40.0
191908
60.0
3012
-30.0
112877
70.0
2221
-20.0
68471
80.0
1663
-10.0
42739
90.0
1262
0.0
27396
100.0
970
10.0
17999
110.0
755
20.0
12099
120.0
594
25.0
10000
130.0
473
30.0
8308
140.0
380
40.0
5819
150.0
308
50.0
4151
HMI error
Model 14 and 18 kW
Number of card flashes
--
Description error
Causes
Solutions
E 881
-
Supply voltage
out of bounds
7
--
protection
DC power surge
Tension
High AC input
Poor input wiring of food
Check power at source
voltage Check power source
wiring
6
--
Protection
DC power supply powered up
Tension
High AC input
Poor input wiring of food
Low voltage
AC input
Poor input wiring
Pre-load contactor problem
17
--
Protection
Lack of AC power supply
voltage
Lack 1 or 2 phase
of three-phase input (R/S/T)
Input voltage<270V
Check source wiring power
Check input voltage value
6.4.
Ohminic values of the different probes
Figure 14 - Ohmic values of the sensors
Содержание ECOMOD AHP60 14 kW
Страница 2: ......