26
PRT-RDE2-PCB
Protege Ethernet 2 Reader Expander
Installation Manual | June 2017
5.2
Trouble Zone Inputs
Each reader expander can monitor up to 16 trouble zones. Trouble zones are used to monitor the status of the
reader expander and in most cases are not physically connected to an external zone. For example, trouble zone
RD001:06 is used to monitor door 1 for a forced open condition and will generate an alarm state if the door is
forced.
The following table details the trouble zones that are configured in the system and the trouble type and group
that they activate.
Zone Number
Description
Type
Group
RDxxx:01
Module Tamper
System Tamper
System
RDxxx:02
AC failure
Power Fault
General
RDxxx:03
Low Battery
Power Fault
General
RDxxx:04
Aux Failure
Power Fault
General
RDxxx:05
Lock Failure
Power Fault
General
RDxxx:06
Door 1 Forced
Forced Door
Access
RDxxx:07
Door 2 Forced
Forced Door
Access
RDxxx:08
Door 1 Left Open
Left Open
Access
RDxxx:09
Door 2 Left Open
Left Open
Access
RDxxx:10
Reader 1 Voltage
Power Fault
General
RDxxx:11
Reader 2 Voltage
Power Fault
General
RDxxx:12
Reader 1 Tamper
System Tamper
System
RDxxx:13
Reader 2 Tamper
System Tamper
System
RDxxx:14
Door 1 Lockout
Attempts
Access
RDxxx:15
Door 2 Lockout
Attempts
Access
RDxxx:16
Module Offline
Module Offline
System
Replace 'xxx' with the appropriate address of the Reader Expander that you are programming.