Combustion system
20
SAFETY AND CONTROL SYSTEMS
For the correct operation of the combustion system through:
–
safety pressure switch on the air side
to stop the combustion in case of fan abnormal operation
–
combustion management system
consisting of a flame electronic supervisor, interconnected with the steam production
control system.
2
5
6
4
12
11
3
8
9
7
1
13
10
15
14
1
Air gas channel
ECOVAPOR
2
Inverterjet gasket
3
Air/gas channel flange gasket
4
Inverterjet head
5
Cone assembly Ø68 ( 2 pcs.)
ECOVAPOR
6
Air filter
ECOVAPOR
350/500(e-1009)
7
Double end nipple 1" x 150 two-wire 25 Mm AISI316
8
Brahma high voltage transformer
9
Ignition electrode cable with plug
10
Ionisation electrode cable with plug
11
Galvanised M8 nut ISO 4033
12
Galvanised 8x15 plain washer UNI 6592
13
Galvanised 5x50 CH Phillips screw cl4.8
14
Galvanised 5x10 plain washer UNI 6592
15
Galvanised raised M5 nut cl8
A
B
ELECTRONIC IGNITION - Models 350 - 1350
1
Ionisation Electrode
2
Ignition Electrode
A
B
PILOT FLAME IGNITION - Models 1700 - 3000
1
Pilot Flame Unit
2
Flame Indicator