v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
code
Description
Action
151
Real-time
clock
error.
1.
Reseat
the
battery.
2.
Clear
CMOS,
see
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
Battery
b.
(Trained
service
technician
only)
System
board
161
Real-time
clock
battery
error.
1.
Reseat
the
battery.
2.
Clear
CMOS,
see
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
Battery
b.
(Trained
service
technician
only)
System
board
162
Device
configuration
error.
1.
Run
the
Configuration/Setup
Utility
program,
select
Load
Default
Settings
,
and
save
the
settings.
2.
Reseat
the
following
components,
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
Battery
b.
Failing
device
(if
the
device
is
a
FRU,
then
the
device
should
be
reseated
by
a
trained
service
technician
only)
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
Battery
b.
Failing
device
(if
the
device
is
a
FRU,
then
the
device
should
be
replaced
by
a
trained
service
technician
only)
c.
(Trained
service
technician
only)
System
board
Chapter
5.
Diagnostics
67
Содержание xSeries 206m
Страница 1: ...IBM xSeries 306m Types 8849 and 8491 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...IBM xSeries 306m Types 8849 and 8491 Problem Determination and Service Guide...
Страница 8: ...vi IBM xSeries 306m Types 8849 and 8491 Problem Determination and Service Guide...
Страница 143: ......
Страница 144: ...Part Number 31R1183 Printed in USA 1P P N 31R1183...