v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
System-error
log
message
Action
Fan
x
Failure
1.
Make
sure
that
fan
x
is
not
obstructed:
2.
Reseat
the
following
components:
a.
Fan
x
b.
Fan
x
cable
3.
Replace
fan
x
.
Flash
of
x
via
y
failed
for
user
z...z
Information
only.
Flash
of
x
by
y
via
z
was
successful...
w
Information
only.
Flash
succeeded
for
x
(address
:
y
)
Information
only.
Hard
drive
x
removal
detected.
Reseat
hard
disk
drive
x
and
restart
the
server.
Hard
drive
x
fault
1.
Run
the
diagnostics
programs.
2.
Replace
hard
disk
drive
x
.
3.
Replace
the
hard
disk
drive
backplane
or
back
panel.
Internal
error
CPU
fault
Information
only.
If
the
message
remains:
1.
(Trained
service
technician
only)
Reseat
the
microprocessor.
2.
(Trained
service
technician
only)
Replace
the
microprocessor.
Invalid
userid
or
password
received.
Userid
is
x
Information
only.
LAN:
Command
mode
tamper
triggered.
Possible
break-in
attempt
Information
only.
LAN:
Ethernet
interface
is
no
longer
active
Information
only.
LAN:
Ethernet
interface
is
now
active
Information
only.
LAN:
Telnet
tamper
triggered.
Possible
break-in
attempt
Information
only.
LAN:
Web
Server
tamper
delay
triggered.
Possible
break-in
attempt
Information
only.
No
ISMP
gateway
defined
for
the
interconnect
network.
RSA
x
is
assuming
the
gateway
Information
only.
OS
Watchdog
response
enabled
by
x
Information
only.
OS
Watchdog
response
disabled
by
x
Information
only.
PFA
Alert,
see
preceding
error
in
system
error
log.
Information
only.
See
the
preceding
entry
in
the
system-error
log.
Possible
ASM
reset
occurred
---
reason
unknown
Information
only.
Power
off
Information
only.
Power
on
Information
only.
PPP_1:
Client
connected
at
nnnn
bps
Information
only.
PPP_1:
User
requested
to
abort
PPP
interface
Information
only.
Chapter
5.
Diagnostics
103
Содержание xSeries 206m
Страница 1: ...IBM xSeries 306m Types 8849 and 8491 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...IBM xSeries 306m Types 8849 and 8491 Problem Determination and Service Guide...
Страница 8: ...vi IBM xSeries 306m Types 8849 and 8491 Problem Determination and Service Guide...
Страница 143: ......
Страница 144: ...Part Number 31R1183 Printed in USA 1P P N 31R1183...