If
it
is
not
possible
to
run
the
tape
cartridge
in
a
different
drive,
perform
the
following
procedures:
1.
Clean
the
failing
drive
and
run
the
drive
diagnostics
(see
“Cleaning
the
Drive
Head”
on
page
31
and
“Function
Code
1:
Run
Drive
Diagnostics”
on
page
33).
If
the
drive
diagnostics
run
successfully,
run
the
Test
Cartridge
&
Media
diagnostic
(see
“Function
Code
E:
Test
Cartridge
&
Media”
on
page
40).
2.
If
the
Test
Cartridge
&
Media
diagnostic
fails,
replace
the
media.
If
it
runs
successfully,
perform
the
operation
that
produced
the
initial
drive
error.