If
the
test
fails,
replace
the
drive
(see
“Removing
a
SCSI
Drive
from
an
Enclosure”
on
page
93).
v
If
the
error
does
not
occur,
connect
one
drive
at
a
time
back
to
the
bus
and
repeat
step
3
for
each
drive
until
you
can
identify
which
drive
is
defective.
Note:
Ensure
that
the
SCSI
terminator
is
always
on
the
last
drive
on
the
SCSI
bus.
4.
Determine
if
the
problem
is
with
only
one
drive
or
with
two
or
more
drives.
v
If
the
problem
is
with
only
one
drive,
run
the
SCSI
wrap
test
on
that
drive
(see
“Function
Code
6:
Run
SCSI
Wrap
Test”
on
page
37).
–
If
the
test
runs
successfully,
replace
the
SCSI
terminator
first,
then
the
SCSI
cable
to
that
drive
and
interposer
(if
installed).
–
If
the
test
fails,
replace
the
drive
(see
“Removing
a
SCSI
Drive
from
an
Enclosure”
on
page
93).
v
If
the
problem
is
with
two
or
more
drives,
locate
the
first
drive
that
has
the
error
and
replace
the
SCSI
cable
that
connects
the
drive
and
the
interposer
(if
installed).
Fixing
an
Intermittent
Error
with
a
Single
Drive
on
a
SCSI
Bus
1.
Replace
the
SCSI
terminator
on
the
drive.
2.
Run
the
operation
that
caused
the
error.
If
the
problem
persists,
the
problem
may
be
with
the
cable.
3.
Isolate
which
cable
is
causing
the
problem
by
replacing
one
cable
at
a
time
and
running
the
operation
that
caused
the
error
after
each
replacement.
If
the
problem
persists
after
all
cables
have
been
replaced,
the
problem
may
be
with
the
drive.
4.
Replace
the
drive
(see
“Removing
a
SCSI
Drive
from
an
Enclosure”
on
page
93).
If
the
problem
persists,
the
problem
is
with
your
server.
Consult
your
server’s
documentation.
Fixing
an
Intermittent
Error
with
Multiples
Drives
on
a
SCSI
Bus
Refer
to
the
server’s
error
logs
to
determine
which
drive
is
the
source
of
the
problem:
v
If
only
one
drive
is
reporting
a
SCSI
failure,
replace
that
drive
(see
“Removing
a
SCSI
Drive
from
an
Enclosure”
on
page
93).
v
If
multiple
drives
are
reporting
SCSI
failures,
the
problem
may
be
with
the
terminator
or
the
SCSI
cables:
–
Replace
the
terminator
and
run
the
operation
that
caused
the
error.
If
the
problem
persists,
the
problem
may
be
with
the
cables.
–
Isolate
which
cable
is
causing
the
problem
by
replacing
one
cable
at
a
time
and
run
the
operation
that
caused
the
error
after
each
replacement.
Resolving
Problems
87
Содержание TotalStorage Ultrium T800
Страница 2: ......
Страница 8: ...vi IBM TotalStorage Ultrium Tape Drive...
Страница 10: ...viii IBM TotalStorage Ultrium Tape Drive...
Страница 14: ...xii IBM TotalStorage Ultrium Tape Drive...
Страница 16: ...xiv IBM TotalStorage Ultrium Tape Drive...
Страница 28: ...12 IBM TotalStorage Ultrium Tape Drive...
Страница 88: ...72 IBM TotalStorage Ultrium Tape Drive...
Страница 108: ...92 IBM TotalStorage Ultrium Tape Drive...
Страница 124: ...108 IBM TotalStorage Ultrium Tape Drive...
Страница 126: ...110 IBM TotalStorage Ultrium Tape Drive...
Страница 130: ...114 IBM TotalStorage Ultrium Tape Drive...
Страница 147: ......
Страница 148: ...Printed in USA GC26 7697 01...