Table
A-1.
Error
codes
on
the
Single-character
Display
(continued)
Error
Code
Cause
and
Action
A
Degraded
operation.
The
tape
drive
determined
that
a
problem
occurred
which
degraded
the
operation
of
the
tape
drive,
but
it
did
not
restrict
continued
use.
If
the
problem
persists,
determine
whether
the
problem
is
with
the
drive
or
the
media.
Note:
The
drive
is
usable,
though
the
Single-character
Display
continues
to
indicate
an
error
and
the
Status
Light
flashes
amber.
The
error
code
may
clear
when
you
cycle
power
to
the
tape
drive
or
place
it
in
maintenance
mode.
To
determine
if
the
problem
is
with
the
drive
hardware,
or
the
tape
media,
perform
the
following
procedures:
1.
If
possible,
run
the
tape
cartridge
in
a
different
drive.
If
the
operation
in
the
other
drive
fails
and
6
or
7
displays,
replace
the
media.
If
the
operation
succeeds,
run
the
Test
Cartridge
&
Media
diagnostic
(see
2.
If
the
Test
Cartridge
&
Media
diagnostic
fails,
replace
the
media.
If
it
runs
successfully,
clean
the
failing
drive
and
run
the
drive
diagnostics
(see
and
Once
you
begin
this
test,
the
diagnostic
begins
the
loop
sequence.
Time
the
first
loop
by
pressing
the
Unload
Button
once
to
stop
the
diagnostic
after
the
completion
of
the
first
loop,
then
record
the
time
it
takes
for
the
test
to
complete.
Compare
the
recorded
time
with
the
″
Approximate
Run
Time
″
above.
If
the
test
runs
successfully
but
the
execution
time
is
significantly
longer
than
the
″
Approximate
Run
Time
″
,
run
If
the
Write
Performance
Test
fails,
replace
the
media
and
exit
maintenance
mode.If
the
drive
diagnostics
run
successfully,
perform
the
operation
that
produced
the
initial
drive
error.
3.
If
the
problem
persists
replace
the
drive.
If
it
is
not
possible
to
run
the
tape
cartridge
in
a
different
drive,
perform
the
following
procedures:
1.
Clean
the
failing
drive
and
run
the
drive
diagnostics
(see
and
Once
you
begin
this
test,
the
diagnostic
begins
the
loop
sequence.
Time
the
first
loop
by
pressing
the
Unload
Button
once
to
stop
the
diagnostic
after
the
completion
of
the
first
loop,
then
record
the
time
it
takes
for
the
test
to
complete.
Compare
the
recorded
time
with
the
″
Approximate
Run
Time
″
above.
If
the
test
runs
successfully
but
the
execution
time
is
significantly
longer
than
the
″
Approximate
Run
Time
″
,
run
If
the
Write
Performance
Test
fails,
replace
the
media
and
exit
maintenance
mode.If
the
drive
diagnostics
run
successfully,
run
the
Test
Cartridge
&
media
diagnostic
(see
2.
If
the
Test
Cartridge
&
Media
diagnostic
fails,
replace
the
media.
If
it
runs
successfully,
perform
the
operation
that
produced
the
initial
drive
error.
3.
If
the
problem
persists
replace
the
drive.
C
The
tape
drive
needs
to
be
cleaned.
Clean
the
tape
drive.
See
The
error
code
clears
when
you
clean
the
tape
drive
or
place
it
in
maintenance
mode.
d
Fiber
AL_PA
conflict.
NOT
SUPPORTED
ON
THIS
DRIVE.
Appendix
A.
Error
Codes
and
Messages
A-5
Содержание System Storage TS2240
Страница 2: ......
Страница 6: ...iv TS2240 Tape Drive Setup Operator and Service Manual...
Страница 10: ...viii TS2240 Tape Drive Setup Operator and Service Manual...
Страница 12: ...x TS2240 Tape Drive Setup Operator and Service Manual...
Страница 14: ...xii TS2240 Tape Drive Setup Operator and Service Manual...
Страница 38: ...2 8 TS2240 Tape Drive Setup Operator and Service Manual...
Страница 76: ...5 6 TS2240 Tape Drive Setup Operator and Service Manual...
Страница 84: ...B 2 TS2240 Tape Drive Setup Operator and Service Manual...
Страница 92: ...C 8 TS2240 Tape Drive Setup Operator and Service Manual...
Страница 118: ...F 6 TS2240 Tape Drive Setup Operator and Service Manual...
Страница 136: ...X 4 TS2240 Tape Drive Setup Operator and Service Manual...
Страница 139: ......
Страница 140: ...Part Number 45E1880 Printed in USA GC27 2151 00 1P P N 45E1880...