2.
To
exit
Maintenance
Mode,
see
The
drive
exits
Maintenance
Mode
automatically
after
it
completes
a
maintenance
function
or
after
10
minutes
if
no
action
has
occurred.
Function
Code
1:
Run
Drive
Diagnostics
Approximate
Run
Time
=
20
minutes
per
loop
Total
Number
of
Loops
=
10
Function
Code
1
runs
tests
that
determine
whether
the
drive
can
properly
load
and
unload
cartridges
and
read
and
write
data.
Once
you
begin
this
test,
the
diagnostic
begins
the
loop
sequence.
Time
the
first
loop
by
pressing
the
Unload
Button
once
to
stop
the
diagnostic
after
the
completion
of
the
first
loop,
then
record
the
time
it
takes
for
the
test
to
complete.
Compare
the
recorded
time
with
the
″
Approximate
Run
Time
″
above.
If
the
test
runs
successfully
but
the
execution
time
is
significantly
longer
than
the
″
Approximate
Run
Time
″
,
run
If
the
Write
Performance
Test
fails,
replace
the
media
and
exit
maintenance
mode.
Attention:
For
this
test,
insert
only
a
scratch
(blank)
data
cartridge
or
a
cartridge
that
may
be
overwritten.
During
the
test,
the
drive
overwrites
the
data
on
the
cartridge.
Note:
If
you
inserted
an
invalid
tape
cartridge
(e.g.
Gen1
or
WORM
media),
error
code
7
appears
in
the
SCD.
If
you
inserted
a
write-protected
cartridge,
or
the
media
has
read-only
compatibility
(e.g.,
Gen2
media),
error
code
P
appears
in
the
SCD.
In
either
case,
the
tape
drive
unloads
the
cartridge
and
exits
Maintenance
Mode
after
the
cartridge
is
removed.
Steps
to
Execute
Run
Drive
Diagnostics:
1.
Place
the
drive
in
Maintenance
Mode.
For
instructions,
see
2.
Press
the
Unload
Button
once
per
second
until
1
appears
in
the
SCD.
(If
you
cycle
past
the
desired
code,
press
the
Unload
Button
once
per
second
until
the
code
reappears.)
3.
Press
and
hold
the
Unload
Button
for
three
or
more
seconds,
then
release
it
to
select
function
1
.
Wait
for
the
SCD
to
change
to
a
flashing
C
.
4.
Insert
a
scratch
(blank)
data
cartridge.
The
SCD
changes
to
a
flashing
1
and
the
test
begins.
During
the
test,
the
drive
will
Unload/Load
the
cartridge.
Do
not
remove
the
cartridge
during
the
test.
v
If
no
error
is
detected,
the
diagnostic
will
loop
and
begin
again.
To
stop
the
loop,
press
the
Unload
Button
for
one
second
and
release.
When
the
loop
ends,
0
temporarily
appears
in
the
SCD.
v
If
an
error
is
detected,
the
Status
Light
flashes
amber
and
the
drive
posts
an
error
code
to
the
SCD.
To
determine
the
error,
locate
the
code
in
3-10
TS2240
Tape
Drive
Setup,
Operator
and
Service
Manual
Содержание System Storage TS2240
Страница 2: ......
Страница 6: ...iv TS2240 Tape Drive Setup Operator and Service Manual...
Страница 10: ...viii TS2240 Tape Drive Setup Operator and Service Manual...
Страница 12: ...x TS2240 Tape Drive Setup Operator and Service Manual...
Страница 14: ...xii TS2240 Tape Drive Setup Operator and Service Manual...
Страница 38: ...2 8 TS2240 Tape Drive Setup Operator and Service Manual...
Страница 76: ...5 6 TS2240 Tape Drive Setup Operator and Service Manual...
Страница 84: ...B 2 TS2240 Tape Drive Setup Operator and Service Manual...
Страница 92: ...C 8 TS2240 Tape Drive Setup Operator and Service Manual...
Страница 118: ...F 6 TS2240 Tape Drive Setup Operator and Service Manual...
Страница 136: ...X 4 TS2240 Tape Drive Setup Operator and Service Manual...
Страница 139: ......
Страница 140: ...Part Number 45E1880 Printed in USA GC27 2151 00 1P P N 45E1880...