Table
A-1.
Error
codes
on
the
Single-character
Display
(continued)
Error
Code
Cause
and
Action
7
Media
error.
The
tape
drive
determined
an
error
occurred
because
of
a
faulty
tape
cartridge
or
an
invalid
tape
cartridge.
Ensure
the
tape
cartridge
is
the
correct
media
type:
v
Ultrium
-1
tape
cartridges
are
not
supported
in
Ultrium-4
tape
drives.
v
Drive
will
not
accept
an
expired
Cleaning
Cartridge.
v
Drive
will
not
accept
a
WORM
cartridge
when
running
diagnostic
tests
in
Maintenance
Mode.
v
Drive
will
not
accept
an
FMR
tape
unless
the
drive
is
performing
v
Drive
will
not
write
over
existing
datasets
on
a
WORM
cartridge.
Ensure
you
are
appending
datasets
on
WORM
media
rather
than
attempting
to
write
over
existing
datasets.
If
the
tape
cartridge
is
the
correct
media
type,
try
another
tape
cartridge.
If
the
problem
occurs
with
multiple
tape
cartridges,
use
the
following
procedure:
1.
If
possible,
run
the
tape
cartridge
in
a
different
tape
drive.
If
the
operation
in
the
other
unit
fails
and
6
or
7
displays,
replace
the
media.
If
the
operation
succeeds,
run
Attention:
When
you
run
the
Test
Cartridge
&
Media
diagnostic,
data
on
the
suspect
tape
is
overwritten.
Use
only
a
scratch
data
cartridge
to
run
the
test.
v
If
the
diagnostic
fails,
replace
the
media.
v
If
the
diagnostic
succeeds,
clean
the
drive
head
(see
and
run
–
If
the
drive
diagnostic
fails,
replace
the
drive.
–
If
the
drive
diagnostic
succeeds,
perform
the
operation
that
produced
the
initial
media
error.
The
error
code
clears
when
you
remove
the
tape
cartridge
or
place
the
tape
drive
in
maintenance
mode.
8
Interface
problem.
The
tape
drive
determined
that
a
failure
occurred
in
the
tape
drive’s
hardware
or
in
the
host
bus.
See
If
8
was
displayed
while
running
″
Function
Code
6:
Host
Interface
Test
″
:
1.
Verify
the
correct
interface
wrap
tool
was
attached
during
the
test.
The
test
will
fail
if
the
correct
interface
wrap
tool
is
not
atttached.
2.
If
the
correct
interface
wrap
tool
was
attached
during
the
test,
replace
the
drive.
The
error
code
clears
when
you
place
the
tape
drive
in
maintenance
mode.
9
Tape
drive
or
RS-422
error.
The
tape
drive
determined
that
a
failure
occurred
in
the
tape
drive’s
hardware
or
in
the
RS-422
connection.
See
or
refer
to
the
Library
procedures
to
isolate
the
problem
to
the
drive.
The
error
code
clears
when
you
place
the
tape
drive
in
maintenance
mode.
A-4
TS2240
Tape
Drive
Setup,
Operator
and
Service
Manual
Содержание System Storage TS2240
Страница 2: ......
Страница 6: ...iv TS2240 Tape Drive Setup Operator and Service Manual...
Страница 10: ...viii TS2240 Tape Drive Setup Operator and Service Manual...
Страница 12: ...x TS2240 Tape Drive Setup Operator and Service Manual...
Страница 14: ...xii TS2240 Tape Drive Setup Operator and Service Manual...
Страница 38: ...2 8 TS2240 Tape Drive Setup Operator and Service Manual...
Страница 76: ...5 6 TS2240 Tape Drive Setup Operator and Service Manual...
Страница 84: ...B 2 TS2240 Tape Drive Setup Operator and Service Manual...
Страница 92: ...C 8 TS2240 Tape Drive Setup Operator and Service Manual...
Страница 118: ...F 6 TS2240 Tape Drive Setup Operator and Service Manual...
Страница 136: ...X 4 TS2240 Tape Drive Setup Operator and Service Manual...
Страница 139: ......
Страница 140: ...Part Number 45E1880 Printed in USA GC27 2151 00 1P P N 45E1880...