Table
3-3.
Diagnostic
and
maintenance
functions
(continued)
Function
Code
Diagnostic
or
Maintenance
Function
Instructions
Location
P
Enable
Post
Error
Reporting:
When
selected,
deferred-check
conditions
are
reported
to
the
host.
U
Disable
Post
Error
Reporting:
When
selected,
deferred-check
conditions
are
NOT
reported
to
the
host.
Entering
Maintenance
Mode
The
drive
must
be
in
maintenance
mode
to
run
drive
diagnostics
or
maintenance
functions.
To
place
the
unit
in
maintenance
mode:
1.
Make
sure
that
no
cartridge
is
in
the
drive.
2.
Press
the
Unload
Button
three
times
within
two
seconds.
0
appears
in
the
Single-character
Display
(SCD),
and
the
Fault
Light
turns
amber.
Note:
If
a
cartridge
is
in
the
tape
drive,
it
will
eject
the
first
time
that
you
press
the
Unload
Button
and
the
drive
will
not
be
placed
in
maintenance
mode.
To
continue
placing
the
drive
in
maintenance
mode,
perform
the
preceding
step.
While
in
Maintenance
Mode,
the
drive
will
not
accept
a
cartridge
unless
the
drive
requests
it.
The
SCD
will
display
a
flashing
C
to
indicate
a
cartridge
needs
to
be
inserted.
Maintenance
functions
cannot
be
performed
concurrently
with
read
or
write
operations.
While
in
maintenance
mode,
the
drive
does
not
receive
SCSI
commands
from
the
server.
Exiting
Maintenance
Mode
The
drive
must
be
in
maintenance
mode
to
run
drive
diagnostics
or
maintenance
functions.
To
exit
maintenance
mode:
1.
Press
and
hold
the
Unload
Button
for
3
or
more
seconds
then
release
the
button
to
take
the
drive
out
of
maintenance
mode.
If
no
error
is
detected,
0
temporarily
appears
in
the
SCD,
then
goes
blank.
The
drive
then
exits
maintenance
mode
and
the
Status
Light
will
return
to
Green.
2.
If
an
error
is
detected,
the
SCD
shows
an
error
code
but
still
exits
maintenance
mode.
To
determine
the
error,
locate
the
code
in
To
clear
the
error,
turn
the
power
off,
then
on
again.
Note:
The
drive
also
exits
maintenance
mode
automatically
after
it
completes
a
maintenance
function
or
after
10
minutes
if
no
action
has
occurred.
Function
Code
0:
Maintenance
Mode
Function
Code
0
makes
the
drive
available
for
running
drive
diagnostics
or
maintenance
functions.
1.
Place
the
drive
in
Maintenance
Mode.
For
instructions,
Chapter
3.
Operating
3-9
Содержание System Storage TS2240
Страница 2: ......
Страница 6: ...iv TS2240 Tape Drive Setup Operator and Service Manual...
Страница 10: ...viii TS2240 Tape Drive Setup Operator and Service Manual...
Страница 12: ...x TS2240 Tape Drive Setup Operator and Service Manual...
Страница 14: ...xii TS2240 Tape Drive Setup Operator and Service Manual...
Страница 38: ...2 8 TS2240 Tape Drive Setup Operator and Service Manual...
Страница 76: ...5 6 TS2240 Tape Drive Setup Operator and Service Manual...
Страница 84: ...B 2 TS2240 Tape Drive Setup Operator and Service Manual...
Страница 92: ...C 8 TS2240 Tape Drive Setup Operator and Service Manual...
Страница 118: ...F 6 TS2240 Tape Drive Setup Operator and Service Manual...
Страница 136: ...X 4 TS2240 Tape Drive Setup Operator and Service Manual...
Страница 139: ......
Страница 140: ...Part Number 45E1880 Printed in USA GC27 2151 00 1P P N 45E1880...