value
to
the
application
requirements.
For
maximum
bandwidth,
set
the
maxphys
parameter
by
adding
the
following
line
to
the
/etc/system
file:
set
maxphys=1048576
(1
MB)
Note:
Do
not
set
the
value
for
maxphys
greater
than
1048576
(1
MB).
Doing
so
can
cause
the
system
to
hang.
Installing
the
Subsystem
Device
Driver
This
section
provides
instructions
for
installing
the
Subsystem
Device
Driver.
For
procedures
about
how
to
install
the
Subsystem
Device
Driver
(SDD),
see
IBM
TotalStorage
Multipath
Subsystem
Device
Driver
User’s
Guide
.
This
publication
describes
how
to
use
the
SDD
on
open-systems
hosts
to
enhance
performance
and
availability
on
the
storage
unit.
The
SDD
creates
redundant
paths
for
shared
logical
unit
numbers
and
permits
applications
to
run
without
interruption
when
path
errors
occur.
It
balances
the
workload
across
paths,
and
it
transparently
integrates
with
applications.
For
information
about
the
SDD,
go
to
http://www-
1.ibm.com/servers/storage/support/software/sdd.html.
Attaching
a
storage
unit
to
a
Sun
host
using
Storage
Traffic
Manager
System
This
section
provides
instructions
for
attaching
a
storage
unit
to
a
Sun
host
using
Storage
Traffic
Manager
System.
The
Storage
Traffic
Manager
System
(STMS)
is
a
multipathing
mechanism
for
native
Sun
systems.
Using
the
DS
CLI,
you
can
specify
Sun
-
Solaris
as
port
profile.
Using
the
Storage
Manager
GUI,
you
can
specify
Sun
servers
(Solaris)
(Sun)
as
host
system
when
attaching
the
storage
unit
to
a
host
operating
with
STMS.
See
the
Sun
Web
site
at
http://www.sun.com
for
up-to-date
documentation.
Configuring
the
Sun
STMS
host
settings
This
section
provides
instructions
for
configuring
the
Sun
STMS
host
settings.
1.
Type
cd
/etc
to
change
to
the
/etc
subdirectory.
2.
Backup
the
system
file
in
the
subdirectory.
3.
Edit
the
system
file
and
set
the
following
parameters
for
servers
with
configuration
that
only
use
Emulex
or
QLogic
adapters:
ssd_io_time
This
parameter
specifies
the
time-out
value
for
disk
operations.
Add
the
following
line
to
the
/etc/system
file
to
set
the
ssd_io_time
parameter
for
the
storage
unit
LUNs:
set
ssd:ssd_io_time=0x78
ssd_max_throttle
This
ssd_max_throttle
parameter
specifies
the
maximum
number
of
commands
that
the
SSD
driver
can
queue
to
the
host
adapter
driver.
The
default
value
is
256,
but
you
must
set
the
parameter
to
a
value
less
than
or
equal
to
a
maximum
queue
depth
for
each
connected
LUN.
Determine
the
value
by
using
the
following
formula:
256
÷
(LUNs
per
adapter)
Chapter
18.
Attaching
to
a
Sun
host
179
Содержание System storage DS6000 Series
Страница 1: ...IBM TotalStorage DS6000 Host Systems Attachment Guide GC26 7680 03...
Страница 2: ......
Страница 3: ...IBM TotalStorage DS6000 Host Systems Attachment Guide GC26 7680 03...
Страница 16: ...xiv DS6000 Host Systems Attachment Guide...
Страница 28: ...xxvi DS6000 Host Systems Attachment Guide...
Страница 30: ...xxviii DS6000 Host Systems Attachment Guide...
Страница 50: ...20 DS6000 Host Systems Attachment Guide...
Страница 84: ...54 DS6000 Host Systems Attachment Guide...
Страница 88: ...58 DS6000 Host Systems Attachment Guide...
Страница 164: ...134 DS6000 Host Systems Attachment Guide...
Страница 170: ...140 DS6000 Host Systems Attachment Guide...
Страница 174: ...144 DS6000 Host Systems Attachment Guide...
Страница 192: ...162 DS6000 Host Systems Attachment Guide...
Страница 212: ...182 DS6000 Host Systems Attachment Guide...
Страница 226: ...196 DS6000 Host Systems Attachment Guide...
Страница 240: ...210 DS6000 Host Systems Attachment Guide...
Страница 248: ...218 DS6000 Host Systems Attachment Guide...
Страница 250: ...220 DS6000 Host Systems Attachment Guide...
Страница 256: ...Taiwan class A compliance statement VS07171L 226 DS6000 Host Systems Attachment Guide...
Страница 297: ......
Страница 298: ...Printed in USA GC26 7680 03...