Chapter 3. IBM System Storage DS4000 and DS5000 hardware
97
IBM System Storage EXP520 (1814-52A) Expansion Unit
Temperature (operating):
– 10 to 35° C (50 to 95° F) at 0 to 914 m (0-3,000 ft.)
– 10 to 32° C (50 to 90° F) at 914 to 2,133 m (3,000-7,000 ft.)
Relative humidity (operating): 8% to 80%
Relative humidity (storage): 5% to 80%
Electrical power (per power supply, system rating):
– Voltage range: 100-240V ac
– Operating current: 6.0 - 2.5 amperes
– Power: 600 watts
– Frequency: 50/60 Hz
Heat dissipation: 1516 BTU per hour (fully configured)
Noise level (normal operation): 6.5 bels
IBM System Storage DS5100 (1818-51A) and DS5300 (1818-53A) storage
subsystems
Temperature (operating):
– 10 to 35 degrees C (50 to 95 degrees F) at 0 to 914 m (0-3,000 ft.)
– 10 to 32 degrees C (50 to 90 degrees F) at 914 to 2,133 m (3,000-7,000 ft.)
Relative humidity (operating): 8% to 80%
Relative humidity (storage): 5% to 80%
Electrical power (per power supply, system rating):
– Voltage range: 100-240V ac
– Operating current: 5.4 - 2.25 amperes
– Power: 580 watts
– Frequency: 50/60 Hz
Heat dissipation: 804 BTU per hour
Noise level (normal operation): 6.75 bels
IBM System Storage EXP5000 (1818-D1A) Expansion Unit
Temperature (operating):
– 10 to 35 degrees C (50 to 95 degrees F) at 0 to 914 m (0-3,000 ft.)
– 10 to 32 degrees C (50 to 90 degrees F) at 914 to 2,133 m (3,000-7,000 ft.)
Relative humidity (operating): 8% to 80%
Relative humidity (storage): 5% to 80%
Electrical power (per power supply, system rating):
– Voltage range: 100-240V ac
– Operating current: 5.4 - 2.25 amperes
– Power: 580 watts
– Frequency: 50/60 Hz
Heat dissipation: 1570 BTU per hour (fully configured)
Содержание System Storage DS4000
Страница 2: ......
Страница 18: ...xvi IBM Midrange System Storage Hardware Guide...
Страница 40: ...22 IBM Midrange System Storage Hardware Guide...
Страница 302: ...284 IBM Midrange System Storage Hardware Guide...
Страница 344: ...326 IBM Midrange System Storage Hardware Guide...
Страница 372: ...354 IBM Midrange System Storage Hardware Guide Figure 7 25 Drive firmware Incompatible...
Страница 490: ...472 IBM Midrange System Storage Hardware Guide...
Страница 522: ...504 IBM Midrange System Storage Hardware Guide...
Страница 544: ...526 IBM Midrange System Storage Hardware Guide...
Страница 561: ...Index 543 Z zoning 129 130...
Страница 562: ...544 IBM Midrange System Storage Hardware Guide...
Страница 564: ...IBM Midrange System Storage Hardware Guide IBM Midrange System Storage Hardware Guide...
Страница 565: ......