Chapter 7. Advanced maintenance, troubleshooting, and diagnostics
375
AIX1 has already finished the reconstruction to the hot spare, as the status is Optimal, but the
AIX2 logical disk is still reconstructing, because it still shows a Degraded status. We can
cross check the information about the drives by using the Drives tab of the profile data
(Example 7-7).
Example 7-7 Profile data: Drives
DRIVES------------------------------
SUMMARY
Number of drives: 32
Current drive types: Fibre (24), Serial ATA (SATA) (8)
BASIC:
TRAY, SLOT STATUS CAPACITY TYPE CURRENT DATA RATE PRODUCT ID
FIRMWARE VERSION
0, 1 Optimal 698,638 GB SATA 4 Gbps ST3750640NS
43W9715 42D0003IBM .AEH
0, 2 Optimal 698,638 GB SATA 4 Gbps ST3750640NS
43W9715 42D0003IBM .AEH
...
0, 16 Optimal 136,732 GB Fibre 4 Gbps MAX3147FD F
S708
85, 1 Failed 465,762 GB SATA 4 Gbps ST3500630NS
39M4557 42D0002IBM .AEH
85, 2 Optimal 465,762 GB SATA 4 Gbps ST3500630NS
39M4557 42D0002IBM .AEH
85, 3 Optimal 465,762 GB SATA 4 Gbps ST3500630NS
39M4557 42D0002IBM .AEH
85, 4 Optimal 465,762 GB SATA 4 Gbps ST3500630NS
39M4557 42D0002IBM .AEH
...
85, 16 Optimal 68,366 GB Fibre 4 Gbps MAX3073FD F
S708
Here we see that the drive in 85,1 has the status Failed and needs to be replaced.
7.4 Migrating arrays between DS storage subsystems
The DS Storage Manager incorporates export and import options to safely move arrays
between different DS storage subSystems without losing data.
This capability is very helpful when you have to upgrade or replace a DS storage subsystem
with a new model or faster disks, but want to preserve the expansions and their data.
The export/import options check that all the conditions to support the disk migration are met
before placing the disks offline and allowing removal of the disks.
Now, instead of using the option to place an array offline, as was the case with previous
versions of Storage Manager, just select the Export Array option on the source machine.
Select the Import Array option on the destination machine to accept the exported disks with
their data.
Содержание System Storage DS4000
Страница 2: ......
Страница 18: ...xvi IBM Midrange System Storage Hardware Guide...
Страница 40: ...22 IBM Midrange System Storage Hardware Guide...
Страница 302: ...284 IBM Midrange System Storage Hardware Guide...
Страница 344: ...326 IBM Midrange System Storage Hardware Guide...
Страница 372: ...354 IBM Midrange System Storage Hardware Guide Figure 7 25 Drive firmware Incompatible...
Страница 490: ...472 IBM Midrange System Storage Hardware Guide...
Страница 522: ...504 IBM Midrange System Storage Hardware Guide...
Страница 544: ...526 IBM Midrange System Storage Hardware Guide...
Страница 561: ...Index 543 Z zoning 129 130...
Страница 562: ...544 IBM Midrange System Storage Hardware Guide...
Страница 564: ...IBM Midrange System Storage Hardware Guide IBM Midrange System Storage Hardware Guide...
Страница 565: ......