40
IBM Midrange System Storage Hardware Guide
3.4.2 DS5000 storage subsystem chassis design
In Figure 3-13, we show a diagram of the DS5000 modules.
Figure 3-13 DS5000 modules
The DS5000 base controller unit is broken down into five primary Field Replacement Units
(FRUs). These components are two controller modules, two controller support modules, and
one interconnect module:
The controller modules contain the ASIC engines, the processors, cache memory,
processor memory, flash memory for cache backup, and additional electronics that allow
the DS5000 to process I/O.
The controller support modules contain the power supplies, battery charging, and fans.
The interconnect module holds the batteries and functions as a hot-swappable midplane.
Controllers use this module to mirror the data cache and share disk loops ports.
All of the five FRUs and their individual components are hot-swappable and can be
interchanged while the system is online, allowing DS5000 users to maximize their uptime.
See the corresponding service guide for specific replacement instructions that take place for
the different FRUs. The latest service guide can be found at:
http://www-947.ibm.com/systems/support/supportsite.wss/selectproduct?taskind=7&bra
ndind=5000028&familyind=5368957&typeind=0&modelind=0&osind=0&psid=sr&continue.x=1
3.4.3 DS5000 storage subsystem front view
The front section of the DS5000 storage subsystem contains the two controller support
modules and the interconnect module.
The controller support modules are the units (FRUs) on the left and right. They each house a
fan and a power supply. In order to replace the fan or power supply, it is necessary to remove
the controller support module and replace the broken or defective part.
Note: A DS5000 storage subsystem has no single point of failure; each module, including
the midplane, is hot-swappable. When any single module fails, I/O operations continue.
Controllers
Controller
support modules
Interconnect
module
Содержание System Storage DS4000
Страница 2: ......
Страница 18: ...xvi IBM Midrange System Storage Hardware Guide...
Страница 40: ...22 IBM Midrange System Storage Hardware Guide...
Страница 302: ...284 IBM Midrange System Storage Hardware Guide...
Страница 344: ...326 IBM Midrange System Storage Hardware Guide...
Страница 372: ...354 IBM Midrange System Storage Hardware Guide Figure 7 25 Drive firmware Incompatible...
Страница 490: ...472 IBM Midrange System Storage Hardware Guide...
Страница 522: ...504 IBM Midrange System Storage Hardware Guide...
Страница 544: ...526 IBM Midrange System Storage Hardware Guide...
Страница 561: ...Index 543 Z zoning 129 130...
Страница 562: ...544 IBM Midrange System Storage Hardware Guide...
Страница 564: ...IBM Midrange System Storage Hardware Guide IBM Midrange System Storage Hardware Guide...
Страница 565: ......