Chapter 3. IBM System Storage DS4000 and DS5000 hardware
83
Use the Prepare for Removal function in the DS Storage Manager Subsystem Management
window or refer to the applicable component replacement instructions for this case. Refer to
Chapter 7, “Advanced maintenance, troubleshooting, and diagnostics” on page 327 for
detailed information.
In most cases when a single component fails, the Service Action Allowed status LED turns on
steadily when the Needs Attention status LED is turned on for the component.
Battery LEDs
Each DS5020 RAID controller has its own battery. There are three LED indicator lights on
each battery:
Service action allowed (blue) (see “Enclosure ID” on page 82 for details)
– Off: Normal status.
– On: Safe to remove.
Battery charging (green)
– On: Battery charged and ready.
– Blinking: Battery is charging.
– Off: Battery is faulted, discharged, or missing.
Needs attention or service action required (amber)
– Off: Normal status.
– On: Controller firmware or hardware requires attention.
Figure 3-60 shows the battery LEDs.
Figure 3-60 Battery LEDs
Attention: If you do a controller replacement, make sure that the controller that you want
to replace is in offline mode or failed before you physically remove it. Using only the
Prepare for Removal function will not change the controller state.
Note: Wait at least two minutes after you replace each component for the controller to
recognize the new component and update the LED status. If the SAA LED is turned on,
you must remove and replace the component in order to get the LED turned off.
Battery charging
(Green)
Service action required
(Amber - Fault)
Service action allowed
(Blue)
Содержание System Storage DS4000
Страница 2: ......
Страница 18: ...xvi IBM Midrange System Storage Hardware Guide...
Страница 40: ...22 IBM Midrange System Storage Hardware Guide...
Страница 302: ...284 IBM Midrange System Storage Hardware Guide...
Страница 344: ...326 IBM Midrange System Storage Hardware Guide...
Страница 372: ...354 IBM Midrange System Storage Hardware Guide Figure 7 25 Drive firmware Incompatible...
Страница 490: ...472 IBM Midrange System Storage Hardware Guide...
Страница 522: ...504 IBM Midrange System Storage Hardware Guide...
Страница 544: ...526 IBM Midrange System Storage Hardware Guide...
Страница 561: ...Index 543 Z zoning 129 130...
Страница 562: ...544 IBM Midrange System Storage Hardware Guide...
Страница 564: ...IBM Midrange System Storage Hardware Guide IBM Midrange System Storage Hardware Guide...
Страница 565: ......