IBM Midrange System Storage Hardware Guide
Firewall Status notifications
are sent when the internal firewall is enabled or disabled by a
root or admin user, as shown in Example 6-4.
Example 6-4 Firewall notification
RSM for Storage (localhost) internal firewall has been disabled.
#
# RSM system type: 7985PBF
# RSM system serial: KQDBXV8
# RSM system name: localhost.localdomain
# RSM modem Key:
K7EuTWmKlqoDuIsgP0xNYiVI13tDtlqoDuZbIvKXYI9pFXY5Le9qDMbeWKFXkn8l093NAZxi96T3ZYr
b21zFSRUkaBO0wEGcJ6NfmYvasl2w
# RSM build: T1.15.4
# RSM location: Datacenter 1
# RSM address: River Street
# RSM city: River CIty
# RSM state: NC
# RSM zip: 00000
# RSM country: United States
# RSM contact name: Max Musterman
# RSM contact phone: 11234567890
# RSM contact hours: 7am - 6pm
# RSM contact timezone: GMT - 6
# RSM contact alt. phone: 1 123 456 7891
# RSM contact alt. hours: 6pm - 7am
# RSM contact e-mail: [email protected]
# RSM contact country: United States
Ping check notifications
are sent when two ping checks in a row fail. Ping checks of the
configured SMTP sever and Management Station are performed each half hour.
Ignored Event notifications
are sent when an event is received that is configured to be
ignored by the RSM for Storage system, and is therefore not reported to IBM Service.
These are events for which a response by IBM Service is not usually required, as shown in
Table 6-1.
Table 6-1 Filtered events
Phone Line Check notification
is sent if the RSM for Storage system cannot verify that an
active phone line is connected to the modem. The check is run daily after midnight local
time.
Event code
Event text
6200
FlashCopy repository logical drive capacity - threshold.
6202
FlashCopy logical drive failed.
None
The persistent monitor running on Host xxxxxxx cannot reach the indicated storage
system.
None
The persistent monitor running on Host xxxxxxx can now reach the indicated
storage system.
4011
The logical drive is not on a preferred path due to ADT/RDAC.
Содержание System Storage DS4000
Страница 2: ......
Страница 18: ...xvi IBM Midrange System Storage Hardware Guide...
Страница 40: ...22 IBM Midrange System Storage Hardware Guide...
Страница 302: ...284 IBM Midrange System Storage Hardware Guide...
Страница 344: ...326 IBM Midrange System Storage Hardware Guide...
Страница 372: ...354 IBM Midrange System Storage Hardware Guide Figure 7 25 Drive firmware Incompatible...
Страница 490: ...472 IBM Midrange System Storage Hardware Guide...
Страница 522: ...504 IBM Midrange System Storage Hardware Guide...
Страница 544: ...526 IBM Midrange System Storage Hardware Guide...
Страница 561: ...Index 543 Z zoning 129 130...
Страница 562: ...544 IBM Midrange System Storage Hardware Guide...
Страница 564: ...IBM Midrange System Storage Hardware Guide IBM Midrange System Storage Hardware Guide...
Страница 565: ......