1.
If possible, this noncritical node error should be
serviced using the management GUI and running
the recommended actions for the service error code.
2.
As the adapter is located on the system board,
replace the node canister using the remove and
replace procedures.
There are a number of possibilities.
a.
If you have deliberately removed the adapter
(possibly replacing it with a different adapter
type), you will need to follow the management
GUI recommended actions to mark the
hardware change as intentional.
b.
As the adapter is located on the system board,
replace the node canister using the remove and
replace procedures.
Possible Cause—FRUs or other cause:
v
Node canister 100%
701
A Fibre Channel adapter has failed.
Explanation:
A Fibre Channel adapter has failed. The
adapter is located on the node canister system board.
This node error does not, in itself, stop the node
canister becoming active in the system. However, the
Fibre Channel network might be being used to
communicate between the node canisters in a clustered
system. Therefore, it is possible that this node error
indicates the reason why the critical node error 550
A
cluster cannot be formed because of a lack of
cluster resources
is reported on the node canister.
Data:
v
A number indicating the adapter location. Location 0
indicates the adapter integrated into the system
board is being reported.
User response:
1.
If possible, use the management GUI to run the
recommended actions for the associated service
error code.
2.
As the adapter is located on the system board,
replace the node canister using the remove and
replace procedures.
Possible Cause-FRUs or other cause:
v
Node canister
702
A Fibre Channel adapter has a PCI
error.
Explanation:
A Fibre Channel adapter has a PCI error.
The adapter is located on the node canister system
board.
This node error does not, in itself, stop the node
canister becoming active in the system. However, the
Fibre Channel network might be being used to
communicate between the node canisters in a clustered
system. Therefore, it is possible that this node error
indicates the reason why the critical node error 550
A
cluster cannot be formed because of a lack of
cluster resources
is reported on the node canister.
Data:
v
A number indicating the adapter location. Location 0
indicates the adapter integrated into the system
board is being reported.
User response:
1.
If possible, use the management GUI to run the
recommended actions for the associated service
error code.
2.
Use the procedures to restart (physically remove
and reseat) a node canister.
3.
As the adapter is located on the system board,
replace the node canister by using the remove and
replace procedures.
Possible Cause-FRUs or other cause:
v
Node canister
703
A Fibre Channel adapter is degraded.
Explanation:
A Fibre Channel adapter is degraded.
The adapter is located on the node canister system
board.
This node error does not, in itself, stop the node
canister becoming active in the system. However, the
Fibre Channel network might be being used to
communicate between the node canisters in a clustered
system. Therefore, it is possible that this node error
indicates the reason why the critical node error 550
A
cluster cannot be formed because of a lack of
cluster resources
is reported on the node canister.
Data:
v
A number indicating the adapter location. Location 0
indicates the adapter integrated into the system
board is being reported.
User response:
1.
If possible, use the management GUI to run the
recommended actions for the associated service
error code.
2.
Use the procedures to restart (physically remove
and reseat) a node canister .
3.
As the adapter is located on the system board,
replace the node canister using the remove and
replace procedures.
Possible Cause-FRUs or other cause:
v
Node canister
701 • 703
150
Storwize V7000: Troubleshooting, Recovery, and Maintenance Guide
Содержание Storwize V7000
Страница 1: ...IBM Storwize V7000 Troubleshooting Recovery and Maintenance Guide GC27 2291 05...
Страница 36: ...18 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 42: ...24 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 46: ...28 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 60: ...42 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 88: ...70 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 176: ...158 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 178: ...160 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 186: ...168 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 187: ......
Страница 188: ...Printed in USA GC27 2291 05...