![IBM Storwize V7000 Скачать руководство пользователя страница 152](http://html2.mh-extra.com/html/ibm/storwize-v7000/storwize-v7000_troubleshooting-and-maintenance-manual_3303571152.webp)
Table 28. Error event IDs and error codes (continued)
Event
ID
Notification
type
Condition
Error
code
045027
E
The drive slot is not running at 6 Gbps
1686
045028
E
The drive slot is dropping frames.
1686
045029
E
The drive is visible through only one SAS port.
1686
045031
E
The drive power control is not functional.
1008
045033
E
The drive slot contains a device that is not responding to
queries.
1685
045034
E
The managed enclosure is not visible from any node
canisters.
1042
045035
E
The electronics in the enclosure has failed.
1694
045036
E
The electronics in the enclosure has experienced a critical
failure.
1008
045037
E
The SAS network has too many errors.
1048
045038
E
The SAS network has too many errors.
1048
045040
W
The firmware update for the enclosure component has
failed.
3015
045041
W
More than one initiator port was detected on the same
strand.
1005
045042
W
The order of the enclosures is different on each strand.
1005
045044
W
Multiple canisters are connected to a single canister port. 1005
045045
W
Canister 1 is connected to canister 2.
1005
045046
W
An enclosure is connected to more than one I/O group.
1005
045047
W
A managed enclosure is connected to the wrong I/O
group.
1005
045048
W
An enclosure is connected to more than one chain.
1005
045049
W
Too many canisters are connected to a strand.
1005
045050
W
The canister is connected to the wrong port.
1005
045051
E
A SAS cable is excluded because of single port active
drives.
1260
045052
W
More than one canister was detected at the same hop
count.
1005
045053
E
The node location is not able to be detected.
1031
045054
E
An enclosure display cannot be updated.
1694
045055
E
There is an enclosure battery fault.
1118
045056
E
An enclosure battery is missing.
1112
045057
E
An enclosure battery is nearing end of life.
1114
045058
E
An enclosure battery is at end of life.
1113
045062
W
An enclosure battery conditioning is required but not
possible.
1131
045063
E
There was an enclosure battery communications error.
1116
045064
W
A SAS port is active, but no enclosures can be detected.
1005
045065
E
There is a connectivity problem between a canister and
an enclosure.
1036
134
Storwize V7000: Troubleshooting, Recovery, and Maintenance Guide
Содержание Storwize V7000
Страница 1: ...IBM Storwize V7000 Troubleshooting Recovery and Maintenance Guide GC27 2291 05...
Страница 36: ...18 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 42: ...24 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 46: ...28 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 60: ...42 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 88: ...70 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 176: ...158 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 178: ...160 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 186: ...168 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 187: ......
Страница 188: ...Printed in USA GC27 2291 05...