![IBM Storwize V7000 Скачать руководство пользователя страница 157](http://html2.mh-extra.com/html/ibm/storwize-v7000/storwize-v7000_troubleshooting-and-maintenance-manual_3303571157.webp)
Table 28. Error event IDs and error codes (continued)
Event
ID
Notification
type
Condition
Error
code
076403
E
One of the two power supply units in the node is
without power.
1097
076502
E
Degraded PCIe lanes on a high-speed SAS adapter.
1121
076503
E
A PCI bus error occurred on a high-speed SAS adapter.
1121
076504
E
A high-speed SAS adapter requires a PCI bus reset.
1122
076505
E
Vital product data (VPD) is corrupt on high-speed SAS
adapter.
1121
076511
E
A high-speed SAS controller is missing.
1032
076512
E
Degraded PCIe lanes on a high-speed SAS adapter.
1032
076513
E
A PCI bus error occurred on a high-speed SAS adapter.
1032
076514
E
A high-speed SAS adapter requires a PCI bus reset.
1034
079500
W
The limit on the number of clustered system secure shell
(SSH) sessions has been reached.
2500
079501
W
Unable to access the Network Time Protocol (NTP)
network time server.
2700
081002
E
An Ethernet port failure has occurred.
1401
082001
E
A server error has occurred.
2100
084000
W
An array MDisk has deconfigured members and has lost
redundancy.
1689
084100
W
An array MDisk is corrupt because of lost metadata.
1240
084200
W
An array MDisk has taken a spare member that is not an
exact match to the array goals.
1692
084201
W
An array has members that are located in a different I/O
group.
1688
084300
W
An array MDisk is no longer protected by an appropriate
number of suitable spares.
1690
084500
W
An array MDisk is offline. The metadata for the inflight
writes is on a missing node.
1243
084600
W
An array MDisk is offline. Metadata on the missing node
contains needed state information.
1243
Node error code overview
Node error codes describe failure that relate to a specific node canister.
Because node errors are specific to a node, for example, memory has failed, the
errors are only reported on that node. However, some of the conditions that the
node detects relate to the shared components of the enclosure. In these cases both
node canisters in the enclosure report the error.
There are two types of node errors: critical node errors and noncritical node errors.
Critical errors
A critical error means that the node is not able to participate in a clustered system
until the issue that is preventing it from joining a clustered system is resolved. This
Chapter 9. Event reporting
139
Содержание Storwize V7000
Страница 1: ...IBM Storwize V7000 Troubleshooting Recovery and Maintenance Guide GC27 2291 05...
Страница 36: ...18 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 42: ...24 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 46: ...28 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 60: ...42 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 88: ...70 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 176: ...158 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 178: ...160 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 186: ...168 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 187: ......
Страница 188: ...Printed in USA GC27 2291 05...