![IBM Storwize V7000 Скачать руководство пользователя страница 103](http://html2.mh-extra.com/html/ibm/storwize-v7000/storwize-v7000_troubleshooting-and-maintenance-manual_3303571103.webp)
Chapter 8. Replacing parts
You can remove and replace customer-replaceable units (CRUs) in control
enclosures or expansion enclosures.
Attention:
If your system is powered on and performing I/O operations, go to
the management GUI and follow the fix procedures. Performing the replacement
actions without the assistance of the fix procedures can result in loss of data or loss
of access to data.
Even though many of these procedures are hot-swappable, they are intended to be
used only when your system is not up and running and performing I/O
operations. If your system is powered on and performing I/O operations, go to the
management GUI and follow the fix procedures. Performing the replacement
actions without the assistance of the fix procedures can result in loss of data or loss
of access to data.
Each replaceable unit has its own removal procedure. Sometimes you can find that
a step within a procedure might refer you to a different remove and replace
procedure. You might want to complete the new procedure before you continue
with the first procedure that you started.
Remove or replace parts only when you are directed to do so.
Be careful when you are replacing the hardware components that are located in the
back of the system that you do not inadvertently disturb or remove any cables that
you are not instructed to remove.
Preparing to remove and replace parts
Before you remove and replace parts, you must be aware of all safety issues.
Before you begin
First, read the safety precautions in the
IBM Systems Safety Notices
. These
guidelines help you safely work with the Storwize V7000.
Replacing a node canister
This topic describes how to replace a node canister.
About this task
Attention:
If your system is powered on and performing I/O operations, go to
the management GUI and follow the fix procedures. Performing the replacement
actions without the assistance of the fix procedures can result in loss of data or loss
of access to data.
Be careful when you are replacing the hardware components that are located in the
back of the system that you do not inadvertently disturb or remove any cables that
you are not instructed to remove.
© Copyright IBM Corp. 2010, 2013
85
Содержание Storwize V7000
Страница 1: ...IBM Storwize V7000 Troubleshooting Recovery and Maintenance Guide GC27 2291 05...
Страница 36: ...18 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 42: ...24 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 46: ...28 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 60: ...42 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 88: ...70 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 176: ...158 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 178: ...160 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 186: ...168 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 187: ......
Страница 188: ...Printed in USA GC27 2291 05...