![IBM Storwize V7000 Скачать руководство пользователя страница 149](http://html2.mh-extra.com/html/ibm/storwize-v7000/storwize-v7000_troubleshooting-and-maintenance-manual_3303571149.webp)
Table 28. Error event IDs and error codes (continued)
Event
ID
Notification
type
Condition
Error
code
010030
E
A managed disk error recovery procedure (ERP) has
occurred. The node or controller reported the following:
v
Sense
v
Key
v
Code
v
Qualifier
1370
010031
E
One or more MDisks on a controller are degraded.
1623
010032
W
The controller configuration limits failover.
1625
010033
E
The controller configuration uses the RDAC mode; this is
not supported.
1624
010034
E
Persistent unsupported controller configuration.
1695
010040
E
The controller system device is only connected to the
node through a single initiator port.
1627
010041
E
The controller system device is only connected to the
node through a single target port.
1627
010042
E
The controller system device is only connected to the
clustered system nodes through a single target port.
1627
010043
E
The controller system device is only connected to the
clustered system nodes through half of the expected
target ports.
1627
010044
E
The controller system device has disconnected all target
ports to the clustered system nodes.
1627
010050
W
A solid-state drive (SSD) failed. A rebuild is required.
1201
010052
E
A solid-state drive (SSD) is offline as a result of a drive
hardware error.
1205
010053
E
A solid-state drive (SSD) is reporting a predictive failure
analysis (PFA).
1215
010054
E
A solid-state drive (SSD) is reporting too many errors.
1215
010055
W
An unrecognized SAS device.
1665
010056
E
SAS error counts exceeded the warning thresholds.
1216
010057
E
SAS errors exceeded critical thresholds.
1216
010058
E
The drive initialization failed because of an unknown
block size or a block size that is not valid; an unknown
capacity or a capacity that is not valid; or was not able to
set the required mode pages.
1661
010059
E
A solid-state drive (SSD) is offline due to excessive
errors.
1311
010060
E
A solid-state drive (SSD) exceeded the warning
temperature threshold.
1217
010061
E
A solid-state drive (SSD) exceeded the offline
temperature threshold.
1218
010062
E
A drive exceeded the warning temperature threshold.
1217
010063
W
Drive medium error.
1321
010066
W
Controller indicates that it does not support descriptor
sense for LUNs that are greater than 2 TBs.
1625
Chapter 9. Event reporting
131
Содержание Storwize V7000
Страница 1: ...IBM Storwize V7000 Troubleshooting Recovery and Maintenance Guide GC27 2291 05...
Страница 36: ...18 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 42: ...24 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 46: ...28 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 60: ...42 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 88: ...70 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 176: ...158 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 178: ...160 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 186: ...168 Storwize V7000 Troubleshooting Recovery and Maintenance Guide...
Страница 187: ......
Страница 188: ...Printed in USA GC27 2291 05...