Verifying operation of the new CP blade
To verify that boot and POST are complete on the new CP blade and that the CP
blade has achieved failover redundancy, complete the following steps.
1.
Enter
slotShow
. The command output shows the new CP blade as “enabled.”
2.
Determine the version by entering
firmwareShow
.
3.
If the firmware versions for both CP blades are the same, skip to step 8 under
“Downloading firmware from an FTP server.”
4.
If the firmware version on the replacement blade does not match that on the
active CP blade, a warning message appears with the results of the
firmwareShow
command. You must bring the replacement blade to the same
firmware level as the active blade using the
firmwareDownload -s
command to
bring it up to the proper level. If you are using an FTP Server to download the
firmware, skip to “Downloading firmware from an FTP server.” If you are
using a USB device to download the firmware, skip to “Downloading firmware
from a USB drive” on page 72.
Downloading firmware from an FTP server
1.
Log out of the active CP blade and log in to the standby CP blade.
2.
Enter
firmwareDownload -s
to download the firmware to the standby CP
blade. The
-s
option also disables the autoreboot, so you will have to
manually issue a reboot after the download finishes to initiate
firmwareCommit
. Enter all requested information (use default values).
3.
To download firmware, go to www.ibm.com/servers/storage/support/san
and select your product, then click on the
Download
tab. Select the
appropriate firmware version and release notes version. Enter all requested
information (use default values):
4.
Enter
firmwareDownloadStatus
to verify that the firmware has been updated.
5.
Ensure that you are still logged in to the standby CP blade (the blade for
which you just changed the firmware level) and type
reboot
. The reboot of the
standby CP will initiate a firmwarecommit to the secondary partition and log
you out.
6.
Log back in to the standby CP blade and type
firmwaredDownloadStatus
on
the standby CP blade to validate a successful commit. This may take up to 10
minutes.
7.
Log out of the standby CP blade and log in to the active CP blade.
8.
Type
haEnable
to re-enable HA on the active CP blade.
Note:
For Fabric OS 6.3.0 and later,
haEnable
will cause the standby CP blade
to reboot. Wait until the power cycles and the POST completes before
moving to the next step.
9.
Type
haShow
and verify that the command output includes “HA Enabled
Heartbeat Up”. If not, re-enter the command until you have verified that
redundancy is achieved.
10.
Type
version
or
firmwareShow
to verify that the firmware version has been
updated.
11.
Pack the faulty CP blade in the packaging provided with the new CP blade for
return to IBM, following local procedures.
12.
Install the chassis door (See “Removing and installing the chassis door” on
page 61.)
Chapter 5. Removing and installing components
71
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Содержание SAN384B
Страница 2: ......
Страница 10: ...viii SAN384B Installation Service and User Guide...
Страница 12: ...x SAN384B Installation Service and User Guide...
Страница 14: ...xii SAN384B Installation Service and User Guide...
Страница 28: ...xxvi SAN384B Installation Service and User Guide...
Страница 38: ...10 SAN384B Installation Service and User Guide...
Страница 60: ...32 SAN384B Installation Service and User Guide...
Страница 78: ...50 SAN384B Installation Service and User Guide...
Страница 88: ...60 SAN384B Installation Service and User Guide...
Страница 146: ...118 SAN384B Installation Service and User Guide...
Страница 158: ...130 SAN384B Installation Service and User Guide...
Страница 164: ...136 SAN384B Installation Service and User Guide...
Страница 168: ...140 SAN384B Installation Service and User Guide...
Страница 176: ...148 SAN384B Installation Service and User Guide...
Страница 181: ......
Страница 182: ...Part Number 45W8160 Printed in USA GC52 1333 02 1P P N 45W8160...
Страница 183: ...Spine information IBM System Storage SAN384B SAN384B Installation Service and User Guide Service information 2499 192...