10.
Connect the power cords to the power supplies and the power outlets.
11.
Replace the chassis door (“Removing and installing the chassis door” on page
61)
12.
Power on the system (“Providing power to the SAN384B” on page 35).
The system performs a power-on self-test (POST). The POST takes a minimum
of three minutes and is complete when LED activity returns to standard state.
13.
Verify that the SAN384B is powered on and POST is complete (all power LED
indicators on the port, control processor, and core switch blades should be a
steady green).
14.
Verify that all components are functioning correctly by checking their LEDs. If
the LEDs do not indicate correct operation, try reinstalling the corresponding
component.
Downloading the configuration
Once the chassis and its various components have been reassembled and powered
back on, use the
configDownload
command to restore the original configuration.
The
configDownload
command can be entered through a Telnet or serial session,
but the SAN384B must have an Ethernet connection to the server name or IP of the
host for the download process to complete. For more information, refer to the
help
configdownload
command or the
Fabric OS Command Reference Manual
.
1.
Log in to the SAN384B as
admin
:
switch:admin>
login
login:
admin
password:
xxxxxxxx
switch:admin>
Note:
If you are using the virtual fabric feature, you should run
configdownload -vf
before running the
configdownload
command in
order to restore the logical switch configuration.
2.
Enter
configDownload -all
command.
switch:admin>
configdownload -all
Server Name or IP Address [host]:
123.123.123.123
User Name [None]:
Admin24
File Name [config.txt]:
config-switch.txt
Password:
xxxxxxxx
download complete
switch:admin>
3.
Reboot the SAN384B.
Verifying correct operation of system
1.
Log in to the SAN384B as
admin
:
switch:admin>
login
login:
admin
password:
xxxxxxxx
switch:admin>
2.
Enter the
slotShow -m
command and verify that all the installed cards are
detected and that their status is operational (enabled).
switch:admin>
slotShow -m
Slot Blade Type
ID
Model Name
Status
--------------------------------------------
1
SW BLADE
51
FC8-48
ENABLED
2
UNKNOWN
VACANT
3
CORE BLADE
46
CR4S-8
ENABLED
4
CP BLADE
50
CP8
ENABLED
5
CP BLADE
50
CP8
ENABLED
100
SAN384B Installation, Service, and User Guide
Содержание SAN384B
Страница 2: ......
Страница 10: ...viii SAN384B Installation Service and User Guide...
Страница 12: ...x SAN384B Installation Service and User Guide...
Страница 14: ...xii SAN384B Installation Service and User Guide...
Страница 28: ...xxvi SAN384B Installation Service and User Guide...
Страница 38: ...10 SAN384B Installation Service and User Guide...
Страница 60: ...32 SAN384B Installation Service and User Guide...
Страница 78: ...50 SAN384B Installation Service and User Guide...
Страница 88: ...60 SAN384B Installation Service and User Guide...
Страница 146: ...118 SAN384B Installation Service and User Guide...
Страница 158: ...130 SAN384B Installation Service and User Guide...
Страница 164: ...136 SAN384B Installation Service and User Guide...
Страница 168: ...140 SAN384B Installation Service and User Guide...
Страница 176: ...148 SAN384B Installation Service and User Guide...
Страница 181: ......
Страница 182: ...Part Number 45W8160 Printed in USA GC52 1333 02 1P P N 45W8160...
Страница 183: ...Spine information IBM System Storage SAN384B SAN384B Installation Service and User Guide Service information 2499 192...