background image

mSFP 41

installing 81
removing 81

mSFP transceivers 41
mSFPs

compatible 41
installing 41

N

network

reconnecting 102

network manageability 9
Network Management System 9
notice, edition ii
notices

attention xviii
caution xvi
danger xiii
environmental xiii, xxii
general 141
IBM 141
patents 141
safety xiii
safety and environmental xiii
types xiii

notices ,danger xiii
notices and labels

safety xiii

notices, attention xviii
notices, caution xvi
NTP server 40

O

ordering the lift tool and the 24–inch load

plate 11

organizing

cables 42

overview 1

P

parameters

configuration 36

part number

24–inch load plate 12
lift tool 12

parts

power cords 126

password 36

changing 36
saving 43

patents 141
PID mode, verifying 41
port blade

FC10-6 45
FC8-16 45
FC8-32 45
FC8-48 45
FC8-64 45
FCOE10-24 45
FX8-24 45
installing 64, 66, 107, 109, 112
monitoring 45
removing 64

port blade

(continued)

status 45

port blades

FC8-16 107
FC8-32 107
FC8-48 107

port blades, FC8-64 109
port groups

trunking 42

port numbering 28, 29
port specifications

FR4-18i routing blade 125

port-side exhaust kit

installing 18

power

cords 126
off 44
SAN384B 35

power specifications 124
power supply

components 56
installing 75, 76
LEDs 56
removing 75
status 56

product

components 2
features 2
features and components 1
hardware components 2
introduction 1
overview 1
reliability 7
serviceability 7
software features 8
specifications 119

product documents xxiii
product specifications 119
providing power to the SAN384B 35

R

rack

safety xix

rack relocation safety xx
rack safety xix
read this first iii
reconnecting

fabric 102
network 102
system 102

recording

critical information 69

reliability 7
removing

ac power xxi
blade filler panel 67
blower assembly 77
cable management finger

assembly 62

chassis door 61
components 61, 97
CP8 blade 68, 69
CR4S-8 blade 72, 73
FC10-6 64
FC8-16 blade 64
FC8-32 blade 64

removing

(continued)

FC8-48 blade 64
FC8-64 64
FCOE10-24 blade 64
FR4-18i 64
FX8-24 blade 64
inter-chassis link (ICL) cable 84, 85
mSFP 81
port blade 64
power supply 75
SAN384B 98
SFP 81
SFP+ 81
WWN bezel 79
WWN bezel and card 78
WWN card 79
XFP 81

removing components 61
requirements

environmental 123
facility 123

routing blade

FR4-18i 45
installing 66, 111
monitoring 45
status 45

S

safety xiii

inspections xxi
labels xiii, xvii

examples xvii

notices xiii
rack xix
rack installation xix
rack relocation xx

safety inspection

external machine checks xxi
internal machine checks xxi

safety inspections xxi
safety labels xvii
safety notices xiii
safety, rack xix
safety, rack installation xix
safety, rack relocation xx
SAN Switch Cabinet C36 11
SAN384B

configuring 33
installation guidelines 13
installing 11, 24
IP addresses 36
library xxiii
physical dimensions 122
providing power 35
removing 98
size 122
starting 33
switch name 38
weight 122

security 8
security features 8
security features table 8
serial connection 35
serial connection, establishing 35
serial console port

login 36

Index

151

Содержание SAN384B

Страница 1: ...and User Guide Service information 2499 192 GC52 1333 02 Read Before Using This product contains software that is licensed under written license agreements Your use of such software is subject to the...

Страница 2: ......

Страница 3: ...IBM System Storage SAN384B Installation Service and User Guide Service information 2499 192 GC52 1333 02...

Страница 4: ...MACHINES CORPORATION PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PART...

Страница 5: ...ade FCOE10 24 v The addition of the 8 Gbps routing blade FX8 24 v 3 way ICL connection configuration was added v An update of how to submit comments on this publication v Battery removal and disposal...

Страница 6: ...or information about storage industry standards see the Storage Networking Industry Association SNIA Web site at www snia org Taiwan Contact Information IBM Taiwan Product Service Contact Info IBM Tai...

Страница 7: ...st kit hardware 20 Installing the SAN384B into the cabinet 24 Port numbering 28 Chassis slots 30 Cable organization 30 Chapter 3 Starting and configuring the SAN384B 33 Providing power to the SAN384B...

Страница 8: ...ng a SAN384B chassis 91 Time required 92 Items required 92 Verifying need for replacement 92 Recording critical SAN384B and SAN information 92 Disconnecting from the network and fabric 96 Removing com...

Страница 9: ...Compliance Statement 144 Avis de conformit la r glementation d Industrie Canada 144 European Union EMC Directive Conformance Statement 144 Germany Electromagnetic Compatibility Directive 145 People s...

Страница 10: ...viii SAN384B Installation Service and User Guide...

Страница 11: ...X8 24 extension blade 49 25 FCOE10 24 blade 49 26 Control processor blade CP8 LEDs 54 27 Core switch blade CR4S 8 55 28 Power supply 57 29 Blower assembly LEDs 58 30 WWN bezel 59 31 Chassis door 62 32...

Страница 12: ...x SAN384B Installation Service and User Guide...

Страница 13: ...LED descriptions 57 13 Blower assembly LED descriptions 58 14 Messages that may indicate WWN card failure 59 15 Commands identifying the WWN card status 79 16 WWN card related system log messages 79...

Страница 14: ...xii SAN384B Installation Service and User Guide...

Страница 15: ...es in the sections that follow v Note These notices provide important tips guidance or advice v Attention notices on page xviii These notices indicate potential damage to programs devices or data v Ca...

Страница 16: ...lace dangerous voltage on the metal shell If any of the conditions are not as described STOP Ensure the improper voltage or impedance conditions are corrected before proceeding D003 DANGER An electric...

Страница 17: ...When possible use one hand only to connect or disconnect signal cables v Never turn on any equipment when there is evidence of fire water or structural damage v Disconnect the attached power cords tel...

Страница 18: ...nt relocation or disposal 500 lbs 227 kg a69i0333 DANGER Heavy equipment personal injury or equipment damage might result if mishandled D006 Caution notices A caution notice calls attention to a situa...

Страница 19: ...or unit is to be performed by trained service personnel only C032 CAUTION For CA residents only IBM recommends installing this product in a room size of 62 cubic meters 2190 cubic feet or larger at 0...

Страница 20: ...s the possibility of damage to a program device or system or to data An exclamation point symbol may accompany an attention notice but is not required A sample attention notice follows Attention Do no...

Страница 21: ...f the customer to ensure that the outlet is correctly wired and grounded to prevent an electrical shock R001 part 1 of 2 CAUTION v Do not install a unit in a rack where the internal rack ambient tempe...

Страница 22: ...y that the route that you choose can support the weight of the loaded rack cabinet Refer to the documentation that came with your rack cabinet for the weight of a loaded rack cabinet Verify that all d...

Страница 23: ...3 Check the power cable for damage 4 Check the external signal cable for damage 5 Check the cover for sharp edges damage or alterations that expose the internal parts of the device 6 Check that any un...

Страница 24: ...slated environmental statements and information regarding product recycling and disposal This document may be provided either in printed version or on the product documentation CD See Removing the bat...

Страница 25: ...s contain information related to this product The documentation may be printed material or may be on the documentation CD that is shipped with the product v IBM System Storage SAN384B Installation Ser...

Страница 26: ...06B R 2498 Model R06 Brocade 7500E SAN04B R 2005 Model R04 Brocade 5300 SAN80B 4 2498 Model B80 Brocade 5100 SAN40B 4 2498 Models B40 and 40E Brocade 300 SAN24B 4 2498 Models B24 and 24E Accessibility...

Страница 27: ...ity information You can view the publications for the SAN384B in Adobe Portable Document Format PDF using the Adobe Acrobat Reader The PDFs are provided on a CD that is packaged with the product An ac...

Страница 28: ...xxvi SAN384B Installation Service and User Guide...

Страница 29: ...itching and two core processing blades v Support for all of the application port blade and control processor CP blades supported in the SAN768B providing flexible system configurations and fewer types...

Страница 30: ...8 24 24 port 12 FC 10 GbE 2 10GbE FCIP extension blade enabling long distance communication over existing IP infrastructure FCOE10 24 24 port 24 10GbE CEE based FCoE blade enabling enhanced connectivi...

Страница 31: ...ent on the port side of the chassis Figure 1 shows a sample configuration of the port side of the SAN384B with four FC8 48 port blades installed 1 FC8 48 port blade example 4x 3 Control processor blad...

Страница 32: ...WWN bezel 3 Blower assembly 2x 2 Power supply 2x 384b002 Figure 2 Port side of the SAN384B with the exhaust kit installed sample configuration 3 2 1 384b003 Figure 3 Blower non port side of the SAN38...

Страница 33: ...between port blades Every port blade connects to each core switch blade There can be up to 256 total ports for port blades Each core switch blade connects to 128 backplane ports Core switch blades hav...

Страница 34: ...rvices and two physical Gigabit Ethernet GbE SFP ports supporting Fibre Channel Over IP FCIP The two physical GbE ports can support up to 16 virtual E_ports FCIP extension blade FC3890 FX8 24 The FX8...

Страница 35: ...etection and correction mechanisms to ensure reliability of data v Error Detection and Fault Isolation EDFI mechanism which checks for encoder errors and fault isolation such as cyclic redundancy chec...

Страница 36: ...manage address assignment routing link initialization fabric initialization link shutdown SAN384B shutdown and the user interface v Integrated Routing optional feature This feature allows any port in...

Страница 37: ...ain ID Upfront login in Web Tools E_port disable Network Manageability The SAN384B has a single domain and is managed as a single element with the Data Center Fabric Manager or Web Tools The SAN384B r...

Страница 38: ...10 SAN384B Installation Service and User Guide...

Страница 39: ...fety instructions Safety notices and labels on page xiii and Rack safety on page xix before performing any installation or service procedures svc00169 55 kg 121 2 lbs CAUTION The weight of this part o...

Страница 40: ...ection that can slide out to extend across the gap between the lift tool and the mounting position inside the C36 cabinet You must provide the following information when you order the lift tool This i...

Страница 41: ...ve a large number of cables that must be carefully routed to minimize problems with installation and replacement of components and in order to maintain the minimum bend radius required for optical cab...

Страница 42: ...tion steps Note Brief assembly instructions for the lift tool are attached to the back of the lift tool Additional instructions are included below in Unpacking and assembling the lift tool on page 15...

Страница 43: ...ring pins v 24 inch load plate with sliding middle section ordered separately to use in place of the 18 inch solid single piece load plate v Anti tip bars v Retention straps v Wheel chocks Assembly in...

Страница 44: ...is middle section is secured in place by two spring loaded pins Familiarize yourself with releasing the pins and sliding this section There are two stops half way extended and fully extended This midd...

Страница 45: ...he port side exhaust kit hardware accessory kit chassis door cable management finger assemblies and foam from the top of the chassis Remove the loose foam blocks from the corners of the chassis Remove...

Страница 46: ...port side exhaust kit in a 2109 C36 cabinet before installing the SAN384B chassis Exhaust kit parts list Table 5 lists items illustrated in Figure 6 on page 19 Table 5 Parts list for port side exhaust...

Страница 47: ...Exhaust 10 32 Clip Nut 10 32 x 5 10 32 x 63 10 32 Retainer Nut Alignment Washer 6 32 x 25 D E F G H I 384b032 Figure 6 Port side exhaust kit assembly for 27 to 31 in 68 58 to 78 74 cm cabinets Chapter...

Страница 48: ...ertical cabinet rails Eight clip nuts and retainer nuts are provided with the exhaust kit and six are provided with the hardware accessory kit Install the lower two nuts at the same relative locations...

Страница 49: ...osition it horizontally and level with the shelf mounting tabs on the outside of the cabinet vertical rails and aligned with the clip nuts you installed earlier c Secure the shelf to the cabinet with...

Страница 50: ...de of the duct facing towards the center of the cabinet 6 Attach the top rail assembly A in Figure 6 on page 19 to the air duct assembly a The top rail assembly can be adjusted to a length of between...

Страница 51: ...rail assembly see Figure 10 a For rails with round holes Use two 10 32 screws with washers E in Figure 6 on page 19 on each end of the top rail assembly Tighten screws according to specifications und...

Страница 52: ...le to the rear of the cabinet Position the lift tool so that the blower assemblies are facing towards the inside of the cabinet and the port side of the chassis facing away from the cabinet see Figure...

Страница 53: ...section is not fully extended Adjust as needed Figure 12 shows a view from inside the cabinet with the middle section of the lift tool load plate extended and the chassis centered on the load plate 9...

Страница 54: ...ft tool away from the cabinet 12 If necessary adjust the rubber strips on the exhaust kit duct to ensure a good seal against the chassis 13 The chassis will be secured to the cabinet with six 10 32 sc...

Страница 55: ...osition the cable management finger assemblies either towards the top of the chassis or towards the bottom of the chassis depending on your requirements for routing cables The third screw for each sid...

Страница 56: ...Port numbering Table 7 provides a list of available port blades for the SAN384B Table 7 Port blades available on the SAN384B Blade label IBM blade name Feature code FC8 16 16 port 8Gb Switch Blade 38...

Страница 57: ...up to eight ports per group Trunking groups are as follows 0 7 8 15 16 23 24 31 32 39 40 47 48 55 and 56 63 v FC10 6 port blade Ports are numbered from 0 through 5 from right to left v FR4 18i router...

Страница 58: ...chassis This pair of cable management finger assemblies can be used to keep the cables from hanging down in front of other blades and to route them away from the exhaust vent of the port side exhaust...

Страница 59: ...up The ports are color coded to indicate which ports can be used in the same ISL Trunking group eight ports marked with solid black ovals alternate with eight ports marked with oval outlines Table 26...

Страница 60: ...32 SAN384B Installation Service and User Guide...

Страница 61: ...ters v IP address and subnet mask for the SAN384B v IP addresses host names subnet masks and gateway addresses for both CP blades v Switch name v Domain ID optional v WWN optional Note The SAN384B WWN...

Страница 62: ...rnet connection on page 38 2 Specify a switch name See Customizing the switch name on page 38 3 Specify a domain ID for the SAN384B See Setting the Domain ID on page 39 4 Set the date and time See Set...

Страница 63: ...omponents on page 45 You can bypass POST by using the fastBoot command You can also disable POST for successive reboots on the SAN384B using the diagDisablePost command Attention To prevent a potentia...

Страница 64: ...login admin Password Please change your passwords now Use Control C to exit or press Enter key to proceed Password was not changed Will prompt again at next login until password is changed swDir admin...

Страница 65: ...r admin ipAddrSet cp 1 Enter the requested information at the prompts The following is a sample IP configuration for the SAN384B sw 0 and the two CP blades cp0 and cp1 swDir admin ipaddrset chassis Et...

Страница 66: ...To complete any additional SAN384B configuration procedures through a Telnet session log in to the SAN384B by Telnet using the admin login The default password is password Customizing the switch name...

Страница 67: ...date and time a switch with an incorrect date and time value still functions properly However because the date and time are used for logging error detection and troubleshooting they should be set cor...

Страница 68: ...h admin tsclockserver ntp1 ntp2 where ntp1 is the IP address or DNS name of the first NTP server which the switch must be able to access The variable ntp2 is the second NTP server and is optional The...

Страница 69: ...se Fabric Watch license Performance Monitor license Trunking license Security license In the example above the license key is AAbbccDDeeFFeeGG Keep a copy of the license key for reference The 64 bit c...

Страница 70: ...how command Managing cables Attention The minimum bend radius should be no smaller than 10x the cable radius Note Contact your IBM representative for options regarding different cable and patch panel...

Страница 71: ...te Passwords are not saved in the configuration file and are not uploaded during a configUpload Password information should be saved in hardcopy in a secure location for reference subject to your secu...

Страница 72: ...instructions on the displayed Fabric OS download pages referring to the Fabric OS Administrator s Guide as needed 3 Enter firmwareDownload s on your to download the firmware to one of the CP blades f...

Страница 73: ...illustrations show the blades oriented horizontally as they are installed in the SAN384B chassis v Figure 18 on page 46 illustrates the FC8 16 port blade v Figure 19 on page 46 illustrates the FC8 32...

Страница 74: ...rt 2 Power LED 4 Port Status LED 1 Status LED 3 Fibre Channel port 2 Power LED 4 Port Status LED 3 4 384b005 1 2 Figure 18 FC8 16 port blade 3 4 384b006 1 2 Figure 19 FC8 32 port blade 46 SAN384B Inst...

Страница 75: ...uires narrower OM 3 LC cables offered by several major manufacturers 32 8 33 9 34 10 35 11 24 0 25 1 26 2 27 3 28 4 29 5 30 6 31 7 32 8 33 9 34 10 35 11 36 12 37 13 38 14 39 15 40 16 41 17 42 18 43 19...

Страница 76: ...1 Status LED 3 Fibre Channel Port 2 Power LED 4 Port Status LED 4 3 2 384b008 1 Figure 22 FC10 6 port blade 48 SAN384B Installation Service and User Guide...

Страница 77: ...9 numbered right to left 4 10 GbE ports 0 1 numbered right to left 1 Power LED 4 Status LED for CEE port 9 2 Status LED 5 CEE port 19 3 CEE port 9 6 Status LED for CEE port 19 7 6 5 4 3 2 1 0 15 14 13...

Страница 78: ...50 SAN384B Installation Service and User Guide...

Страница 79: ...n Power LED Steady green Blade is enabled No action required No light LED is off Blade is not powered on Ensure that the blade is firmly seated and either the thumbscrew is fully engaged or the slider...

Страница 80: ...shing green on 1 second then off 1 second Port is online but segmented indicating a loopback plug or cable or an incompatible switch Verify that the correct device is attached to the SAN384B Fast flas...

Страница 81: ...ine with traffic flowing through port No action required Steady amber Port is receiving light but it is not online yet Reset the port by doing a shutdown and no shutdown sequence from a cmsh session S...

Страница 82: ...ify that the power LED is on Steady amber CP blade is faulty or the switch is still booting Ensure that the blade is firmly seated and the switch has completed booting If the LED remains amber contact...

Страница 83: ...type the ifModeSet command Steady green Ethernet link speed is 100 1000 Mbps No action required Active CP Steady blue Active CP blade No action required No light LED is off Standby CP blade No action...

Страница 84: ...nd then off 1 2 second Environmental range exceeded Check for out of bounds environmental condition and correct it LINK LED No light LED is off No ICL or ICL cable present but no connection Ensure tha...

Страница 85: ...ail Replace the power supply Blower assembly status To determine the status of a blower assembly 1 Check the LED indicators on the blower assembly see Figure 29 on page 58 The LED patterns may tempora...

Страница 86: ...assembly has a failure full or partial Replace the blower assembly Slow flashing amber on 2 sec then off 2 sec Blower assembly is not seated correctly or is faulty Pull the unit out and reseat it If...

Страница 87: ...ader access 0x24c fabos Switch switchname error EM I2C_TIMEOUT 2 WWN 1 I2C timed out state 0x4 WWN unit is being faulted 0x24c fabos Switch switchname Critical EM WWN_UNKNOWN 1 Unknown WWN 2 is being...

Страница 88: ...60 SAN384B Installation Service and User Guide...

Страница 89: ...re switch blade on page 72 v Removing and installing a power supply on page 75 v Removing and installing a blower assembly on page 77 v Removing and installing a WWN bezel and WWN card on page 78 v Re...

Страница 90: ...less than five minutes A 1 Phillips screwdriver is required Removing a cable management finger assembly To remove the cable management finger assembly 1 Remove the chassis door 2 Remove the cables fr...

Страница 91: ...abinet vertical rails two of which are also used to secure the cable management assembly The holes on the assembly will only match two of the holes on the chassis at a time This will allow the cable m...

Страница 92: ...6 blade only transceivers as needed v Optical cables as needed Removing a blade To remove a port or router blade do the following Attention Follow ESD precautions see ESD precautions on page xviii fo...

Страница 93: ...8 16 FC8 32 FC8 48 and FC8 64 port blades and the FX8 24 and FCOE10 24 application blades Unscrew the two thumbscrews from the left and right ejectors on the blade using the Phillips screwdriver Unscr...

Страница 94: ...uides in the slot and slide the blade into the slot until it is firmly seated v For FC10 6 port blade and FR4 18i router blades Open the ejectors to approximately 45 degrees align the flat side of the...

Страница 95: ...panels Removing a filler panel Attention A filler panel should be removed only when being replaced with a port blade or new filler panel Any slot that is not occupied by a blade should be occupied by...

Страница 96: ...the SAN384B configuration v 2 Phillips screwdriver v Replacement CP blade The SAN384B requires the CP8 blade Verifying the need for replacement Confirm that you need to install the CP blade The follo...

Страница 97: ...tus LED on the currently active CP blade is no longer lit b Confirm the completion of the failover by running the hashow command c Log in to the new active CP blade d Run the firmwareShow command to c...

Страница 98: ...es to approximately 45 degrees Orient the CP blade so that the handles are toward you and the flat metal side is on the bottom 2 Align the flat metal side of the CP blade inside the left and right bla...

Страница 99: ...se default values 3 To download firmware go to www ibm com servers storage support san and select your product then click on the Download tab Select the appropriate firmware version and release notes...

Страница 100: ...rmwareDownloadStatus to verify that the firmware has been updated 7 Ensure that you are still logged in to the standby CP blade the blade for which you just changed the firmware level and type reboot...

Страница 101: ...driver messages Platform Error messages that indicate a problem with a core switch blade Function fail messages for the core switch blade master For more information about error messages refer to the...

Страница 102: ...dle using the Phillips screwdriver 4 Turn the core switch blade on by sliding the ON OFF switch in the left handle to the left to cover the thumbscrew 5 Verify that the power LED is green this might r...

Страница 103: ...air circulation for system cooling Time and items required The installation procedure for each power supply takes less than 5 minutes A power supply unit or filler panel is required for the power supp...

Страница 104: ...placing the power supply insert and attach a power supply filler panel into the slot Note Two power supplies are required to provide redundancy protecting against potential data loss Installing a powe...

Страница 105: ...inutes The following items are required for the blower assembly installation v Replacement blower assembly v 2 Phillips screwdriver Removing a blower assembly To remove a blower assembly do the follow...

Страница 106: ...ling a WWN bezel and WWN card Note The World Wide Name WWN cards contain fully redundant circuits and normally do not require replacement Two WWN cards are located beneath the WWN bezel Time and items...

Страница 107: ...card chassisShow Ethernet and Fibre Channel IP address information for the CP blades ipAddrShow ipAddrSet History log information historyShow historyLastShow Name of switch switchName Name of chassis...

Страница 108: ...d data please wait about 25 seconds for further instruction Please install the new FRU now If this session lost for any reason please re enter the frureplace command and follow the instructions to com...

Страница 109: ...minutes after WWN card installation to begin functioning 6 Install the WWN bezel Orient the bezel on the chassis Figure 40 on page 80 Insert and tighten the two screws 7 Pack the faulty WWN card in th...

Страница 110: ...inserted into ports intended for SFP or SFP transceivers They will be faulted on power up for Fabric OS 6 4 0 and later Removing an SFP SFP or XFP optical transceiver To remove an SFP SFP or XFP FC6 1...

Страница 111: ...ther removed from or inserted into the mSFP while the transceiver is out of the switch or blade Removing an mSFP transceiver Note The mSFP transceivers are used only with the FC8 64 port blade Narrowe...

Страница 112: ...7 ICL connector port LEDs LED purpose Color Status Recommended action LINK LED No light LED is off No ICL or ICL cable present but no connection Ensure that the ICL cable is correctly installed Steady...

Страница 113: ...he latch release tabs pull each plug on the cable from its respective socket on the SAN384B core switch blades CR4S 8 or SAN768B core switch blades CR8 4 Repeat for each cable that requires replacemen...

Страница 114: ...hassis It is also acceptable to attach the cables from slot 3 on one chassis to slot 3 on the second chassis or slot 6 to slot 6 as long as the left to right top to bottom rule is followed Figure 47 o...

Страница 115: ...Control processor blades CP8 4 Port blades 5 ICL connector ICL 1 6 ICL connector ICL 0 7 ICL cables 8 Chassis 2 1 2 5 6 3 4 7 8 384b026 Figure 45 ICL cable connections between two SAN384B chassis Chap...

Страница 116: ...ocessor blades CP8 4 Port blades 5 ICL connector ICL 1 6 ICL connector ICL 0 7 ICL cables 8 Chassis 2 SAN768B 1 2 5 6 3 4 7 8 384b027 Figure 46 ICL cable connections between a SAN384B chassis and a SA...

Страница 117: ...es CR4S 8 3 Chassis 2 SAN768B 4 Chassis 3 SAN768B 5 ICL connector ICL 1 2 5 6 2 2 6 3 5 6 5 4 1 384b054 Figure 47 3 way ICL cable connections between a SAN384B chassis and two SAN768B chassis Chapter...

Страница 118: ...es CR4S 8 3 Chassis 2 SAN768B 4 Chassis 3 SAN384B 5 ICL connector ICL 1 6 ICL connector ICL 0 5 6 3 5 2 5 6 1 2 6 2 4 384b055 Figure 48 3 way ICL cable connections between a SAN768B chassis and two SA...

Страница 119: ...the other set is connected to the blades in the high order slots slot 5 in the SAN384B and slot 8 in the SAN768B Keeping the sets apart in this manner minimizes the cable confusion Removing and repla...

Страница 120: ...lb v A surface to place the old chassis on such as a second lift or the pallet originally provided with the old chassis v 2 Phillips screwdriver Verifying need for replacement Verify that replacement...

Страница 121: ...n of the txt files which are created by the customer and are not called out in the supportShow results For detailed information about Fabric OS commands refer to the Fabric OS Command Reference Use a...

Страница 122: ...the virtual fabric feature run configUpload vf before running the configUpload command in order to save the logical switch configuration Enter configUpload all then enter the requested information at...

Страница 123: ...nd Serial Num are listed under Chassis WWN Unit 1 If the current WWN cards are the original cards the factory serial number listed is the same as the chassis serial number switch admin chassisshow Cha...

Страница 124: ...ion can be used after the SAN384B is restored to the fabric to verify that no unintentional changes have occurred to the fabric switch admin supportshow version 6 4 0 output truncated switch admin 9 R...

Страница 125: ...ve the core switch blades Removing and installing a CR4S 8 core switch blade on page 72 4 Remove the control processor blades Removing and installing a CP8 control processor blade on page 68 5 Remove...

Страница 126: ...assis connecting the chassis to the cabinet rails Remove the screws attaching the L brackets to the cabinet rails and the screws attaching the L brackets to flat mounting plates that are connected to...

Страница 127: ...assis may be shipped to a new location while installed in the cabinet it is recommended that you attach the shipping brackets to any replacement chassis These shipping brackets consist of flat mountin...

Страница 128: ...ection to the server name or IP of the host for the download process to complete For more information refer to the help configdownload command or the Fabric OS Command Reference Manual 1 Log in to the...

Страница 129: ...dule 34 3 2 0b2200 __ N8 No_Module 35 3 3 0b2300 __ N8 No_Module 36 3 4 0b2400 id N4 Online F Port 10 00 00 00 c9 51 00 2d 37 3 5 0b2500 __ N8 No_Module switch admin 4 Verify that all the IP address i...

Страница 130: ...sponds to the port and position it so that the key the ridge on one side of the cable connector is aligned with the slot in the transceiver then insert the cable into the transceiver until the latchin...

Страница 131: ...rlier In particular look for differences in the following v Device types v Number of devices v ISL and port states v Number of switches in the fabric 3 Resolve any issues or unintentional changes to t...

Страница 132: ...the number of ports in the chassis Table 19 Cable routing table for SAN384B 64 ports shown Slot Port Cable labels Connected device Slot Port of device Slot Port Switch end Device end 0 1 2 3 4 5 6 7...

Страница 133: ...Local regulations may require removal of the battery before recycling or disposing of the product Follow these steps to remove the battery from the product 1 Remove any installed modules 2 Remove any...

Страница 134: ...646 R645 R639 R641 R642 R635 R79 R74 R75 R81 R80 R82 R83 R89 R88 R65 R66 R72 R71 R73 R137 R143 R142 R76 R77 R78 R84 R85 R87 R86 R67 R68 R70 R69 R138 R139 R141 R140 C6 C4 C5 R358 R362 R335 R332 R338 R3...

Страница 135: ...e 16 32 or 48 ports These features can be installed while the SAN384B is operational Attention Follow these precautions for all procedures in this section to avoid damaging the port blades or chassis...

Страница 136: ...trator s Guide 4 Remove the filler panel or port blade Refer to Removing a blade on page 64 or Removing and installing blade filler panels on page 67 Attention A filler panel should be removed only wh...

Страница 137: ...chassis Time required 20 minutes or more per port blade due to port and cable density Items required v ESD electrostatic discharge grounding strap v Workstation computer v Port blade v 2 Phillips scr...

Страница 138: ...ed only with the FC8 64 port blade Narrower OM 3 LC cables are used to connect the FC8 64 These cables are offered by several major manufacturers Contact your IBM representative for options regarding...

Страница 139: ...ic discharge grounding strap v Workstation computer v Router blade v Phillips screwdriver v Small form factor pluggable SFP transceivers as needed v Optical cables as needed Procedures Follow the link...

Страница 140: ...abric OS Administrator s Guide which is located on the product documentation CD FC3870 Installing an FC10 6 10 Gb blade This feature can be installed while the SAN384B is operational Attention Follow...

Страница 141: ...nstalling port and application blades on page 64 and Removing and installing blade filler panels on page 67 Attention A filler panel should be removed only when being replaced with a port blade or new...

Страница 142: ...ounding strap v Workstation computer v Port blade v Phillips screwdriver v SFP transceivers as needed v Optical cables as needed Procedures Follow the links in the steps below to complete this install...

Страница 143: ...feature can be installed while the SAN384B is operational Attention Follow these precautions for all procedures in this section to avoid damaging the port blades or chassis v Wear a grounded ESD stra...

Страница 144: ...strip from the blade contacts if any before installing the blade 6 Repeat steps 1 5 for additional blades if any 7 Install the transceivers Removing and installing transceivers on page 81 and confirm...

Страница 145: ...e using to connect the two chassis Refer to Figure 45 on page 87 and Figure 46 on page 88 for two possible valid options 5 Remove the EMI plugs from the ICL sockets that you will be connecting Save th...

Страница 146: ...118 SAN384B Installation Service and User Guide...

Страница 147: ...Channel protocol FC PH Fibre Channel Physical and Signalling Interface standard Modes of operation Fibre Channel Class 2 Class 3 and Class F Fabric initialization Complies with FC SW 5 0 FC IP IP ove...

Страница 148: ...runk group to form a 64 Gbps trunk Aggregate bandwidth 3 Tbps per chassis Switch latency FC8 16 FC8 32 FC8 48 FC8 64 blades 2 1 msec any port to any port at 8 Gbps cut through routing For the FR4 18i...

Страница 149: ...BM SAN web page http www ibm com systems storage san v Select the SAN384B product link v On the SAN384B product page click the Interoperability Matrix link v In the Interoperability matrix click the T...

Страница 150: ...lb System blade and FRU weights Table 23 lists the weights of the compatible blades and other FRUs Table 23 System FRU weights FRU Weight CP blade CP8 3 0 kg 6 6 lb CR blade CR4S 8 3 27 kg 7 2 lb FC8...

Страница 151: ...ceptable storage and transportation environments CAUTION For CA residents only IBM recommends installing this product in a room size of 2190 cubic feet 62 cubic meters or larger at 0 4 ACH ventilation...

Страница 152: ...Ports fabric ports FL_Ports fabric loop enabled or E_Ports expansion ports The ports meet all required safety standards Power specifications DANGER Multiple power cords The product might be equipped w...

Страница 153: ...istance 62 5 microns OM1 50 microns OM2 50 microns OM3 9 microns SWL SFP 1 Gbps 300 m 984 ft 500 m 1640 ft 860 m 2821 ft N A mSFP SFP SFP 2 Gbps 150 m 492 ft 300 m 984 ft 500 m 1640 ft N A mSFP SFP SF...

Страница 154: ...er in use The GbE ports are capable of operating at 1 Gbps The eight virtual FCIP Fibre Channel links over each physical GbE connection share this bandwidth Power cords Two power cords for connecting...

Страница 155: ..._Ports and do not merge if they are configured as VEX_Ports If VE_Ports are used in a Fibre Channel Routing Services backbone fabric configuration then the backbone fabric merges but the EX_Port attac...

Страница 156: ...on and tape pipelining over FCIP licensable v FICON CUP licensable v Virtual E_ports v FCIP QoS v Support for 200 ms RTT on a limited number of GbE ports v Adaptive Rate Limiting licensable v TCP perf...

Страница 157: ...ade Refer to the Fabric OS Administrator s Guide for information on configuring these features The FCOE10 24 blade supports only optical cabling and transceivers SFP The FCOE10 24 blade provides the f...

Страница 158: ...130 SAN384B Installation Service and User Guide...

Страница 159: ...OS Messages Reference and the Fabric OS Administrator s Guide for more information v Enter the sensorShow command to determine the status of the hardware components v Run diagnostic tests see Diagnost...

Страница 160: ...blade is rebooted it fails over to the standby CP blade POST To verify that POST has completed without error v Verify that all LEDs return to a normal state after POST completes see Chapter 4 Monitori...

Страница 161: ...ch diagnostic test can be implemented by entering the related command through a Telnet or serial session For a list of diagnostic tests and commands refer to the Fabric OS Command Reference Manual and...

Страница 162: ...peed negotiation set up by the network Specify the CP Ethernet link speed by entering the ifModeSet command Configuration data is inaccurate or cannot be accessed Chassis was powered off on while the...

Страница 163: ...down port blades as necessary to return the temperature readings to the operating ranges Blades might be faulty Enter the slotShow command to determine status For more information enter the diagDisab...

Страница 164: ...136 SAN384B Installation Service and User Guide...

Страница 165: ...ade v Figure 53 on page 138 shows an FC8 48 port blade v Figure 54 on page 138 shows an FC8 64 port blade v Figure 55 on page 138 shows an FC10 6 port blade v Figure 56 on page 138 shows an FR4 18i ro...

Страница 166: ...left 1 FC ports 0 15 right to left 2 GbE ports GE0 right GE1 left 3 2 1 4 384b063 Figure 53 FC8 48 port blade 8 7 3 2 1 5 6 4 384b064 Figure 54 FC8 64 port blade FC 10 6 2 3 4 5 1 0 384b065 Figure 55...

Страница 167: ...ft 7 1 GbE ports 4 9 numbered right to left 4 10 GbE ports 0 1 numbered right to left 1 Status LED 3 10 GbE FCoE ports 0 11 numbered right to left 2 Power LED 4 10 GbE FCoE ports 12 23 numbered right...

Страница 168: ...140 SAN384B Installation Service and User Guide...

Страница 169: ...cal law INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF NON IN...

Страница 170: ...products was obtained from the suppliers of those products their published announcements or other publicly available sources IBM has not tested those products and cannot confirm the accuracy of perfor...

Страница 171: ...rks of Adobe Systems Incorporated in the United States and or other countries Java and all Java based trademarks and logos are trademarks of Sun Microsystems Inc in the United States other countries o...

Страница 172: ...void the user s authority to operate the equipment This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interfer...

Страница 173: ...en werden Warnung Dieses ist eine Einrichtung der Klasse A Diese Einrichtung kann im Wohnbereich Funk St rungen verursachen in diesem Fall kann vom Betreiber verlangt werden angemessene Ma nahmen zu e...

Страница 174: ...the user may be required to take corrective actions Japan Electronics and Information Technology Industries Association JEITA Statement Japanese Electronics and Information Technology Industries Asso...

Страница 175: ...Statement Australia and New Zealand Class A Statement Attention This is a Class A product In a domestic environment this product might cause radio interference in which case the user might be require...

Страница 176: ...148 SAN384B Installation Service and User Guide...

Страница 177: ...serial 35 connection Ethernet 38 control processor blade components 53 LEDs 54 status 53 54 cords power 126 core switch blade components 55 LEDs 56 status 55 56 CP8 blade components 53 LEDs 54 status...

Страница 178: ...lation planning 11 preparation 11 installation guidelines 13 installing 84 blade filler panel 67 blower assembly 77 78 cable management finger assembly 62 chassis components 99 chassis door 61 compone...

Страница 179: ...fications 119 product documents xxiii product specifications 119 providing power to the SAN384B 35 R rack safety xix rack relocation safety xx rack safety xix read this first iii reconnecting fabric 1...

Страница 180: ...ting blades 51 WWN card 59 strap ESD 109 111 112 114 115 switch name changing 38 synchronizing time zone 40 system architecture 119 system component status 45 system components monitoring 45 T time se...

Страница 181: ......

Страница 182: ...Part Number 45W8160 Printed in USA GC52 1333 02 1P P N 45W8160...

Страница 183: ...Spine information IBM System Storage SAN384B SAN384B Installation Service and User Guide Service information 2499 192...

Отзывы: