To verify the repair of a system that is currently powered on and that has an operating system loaded,
go to step 5.
1.
Power on the server and all attached I/O enclosures.
Did all the enclosures power on?
Yes:
Go to step 3.
No:
Continue with the next step.
2.
Choose from the following options:
v
If the original problem was that an enclosure would not power on and you have another FRU to replace, locate
and replace the next field-replaceable unit (FRU).
v
If the next FRU in the FRU list is an isolation procedure, perform the isolation procedure.
v
If the original problem was that an enclosure would not power on and you have an isolation procedure to
complete, perform the isolation procedure.
v
If the original problem was that an enclosure would not power on and there are no more FRUs or isolation
procedures in the FRU list, contact your next level of support.
v
If you have a new problem, perform problem analysis and repair the new problem.
3.
Load the operating system.
Did the operating system load successfully?
Yes:
Go to step 5.
No:
Continue with the next step.
4.
Choose from the following options:
v
If the original problem was a failing disk drive that contained the operating system software, go to step 5.
v
If the original problem was that the operating system would not load and you have another FRU to replace, go to
your FRU locations section to locate the next FRU.
v
If the next FRU in the FRU list is an isolation procedure, perform the isolation procedure.
v
If the original problem was that the operating system would not load and you have an isolation procedure to
complete, perform the isolation procedure.
v
If the original problem was that the operating system would not load and there are no more FRUs or isolation
procedures in the FRU list, contact your next level of support.
v
If you have a new problem, perform problem analysis and repair the new problem.
5.
Choose from the following options:
v
v
“Verifying the repair in Linux” on page 176
v
“Verifying a repair by using an IBM i system or logical partition” on page 174
v
“Verifying the repair on an IBM PowerKVM system” on page 176
v
“Verifying the repair from the management console” on page 177
Verifying the repair in AIX
You can use this procedure to verify that a repair is complete using the AIX operating system.
Use this maintenance analysis procedure (MAP) to check out the server after a repair is completed.
1.
Did you replace a disk drive in the root volume group?
Common procedures for removing and replacing the system backplane
171
Содержание Power Systems 8247-42L
Страница 1: ...Power Systems System backplane for the 8247 42L 8286 41A or 8286 42A IBM...
Страница 2: ......
Страница 3: ...Power Systems System backplane for the 8247 42L 8286 41A or 8286 42A IBM...
Страница 8: ...vi System backplane...
Страница 18: ...xvi System backplane...
Страница 23: ...1 2 or 1 2 or 1 2 3 4 or 1 2 3 4 or System backplane 5...
Страница 80: ...1 2 or 1 2 or 1 2 3 4 or 1 2 3 4 or 62 System backplane...
Страница 214: ...196 System backplane...
Страница 226: ...208 System backplane...
Страница 227: ......
Страница 228: ...IBM...